Telecor VS1 Installation, Configuration & Operating Manual page 133

Pc-based expandable
Table of Contents

Advertisement

relay {1|2} {time}—Closes the Relay 1 or Relay 2 contacts on PEU A for the time
specified. Note that the value is in hundredths of a second. For example, relay 1 100 would
close Relay1 for 1 second.
ren {filename} {newfilename}—Renames the specified file using the path and new file
name specified. This command supports path names, but fails if the new file name already exists.
rop {off|on|0|1}—Controls the Ring Over Pager feature. With rop on, incoming CO calls
ring over the Zone1 and Zone2 contacts on PEU A. Setting rop off disables this feature. The
Ring Over Pager port property must be enabled in Port Configurations for this feature to work.
(Default = OFF/0)
set—Displays many of the current system settings.
set aaidletime={n}—Sets the inactivity timeout for COs connected to Auto Attendants. If a
DTMF tone is not detected within AAIDLETIME seconds, the VS1 system terminates the call on
that CO. (Valid range = 60–3600 seconds, default = 600 seconds)
set animode={0|1}—Reserved for Telecor Technical Support use. Do not change this setting.
set autopagetime={n}—Sets the system default Auto Page time for ports configured to Auto
Page. A call must ring at an extension for AUTOPAGETIME seconds prior to the first Auto Page.
(Valid range = 0–120 seconds, default = 10 seconds)
set autopagerepeat={n}—Sets the system default Auto Page repeat interval. A setting of 0
disables Auto Page repeats. (Valid range = 0–120 seconds, default = 0 seconds)
set aavolin={n}—Sets the incoming DSP volume level for COs connected to voice channels
(i.e. Auto Attendants, Voice Mail). This value is in addition to any change made through the dsp vol
co ={n} in command. (Valid range = -12 to 12 dB, default = 0 dB)
set aavolout={n}—Sets the outgoing DSP volume level for COs connected to a voice
channel (i.e. Auto Attendants, Voice Mail). This value is in addition to any change made in the dsp
vol co ={n} out command. (Valid range = -12 to 12 dB, default = 0 dB)
set cidformat={0|1}—Sets the format of Caller ID in the SMDR files. Setting this value to
0 causes the area code to be enclosed within parentheses while a setting of 1 includes only the raw
digits. (Default = 1)
set coholdtime={n}—Sets the system default held call and parked call recall timer. A held or
parked call rings back to the station that placed it there after this timer expires. (Valid range = 20–
3600 seconds, default = 300 seconds)
set cpdans1={n}—Reserved for Telecor Technical Support use. Do not change this setting.
set cpdans2={n}—Reserved for Telecor Technical Support use. Do not change this setting.
set dialmindigits={n}—Sets the minimum number of digits that must be dialed after
pressing 9. Dialing fewer than DIALMINDIGITS results in the call being toll restricted. (Valid
range = 1–11 digits, default = 4 digits)
set dialtimerdigits={n}—Sets the number of digits after pressing 9 at which the dial
buffer switches from using DIALTIME1 to using DIALTIME2 as its timeout value. (Valid range =
1–11 digits, default = 7 digits)
set dialtime1={n}—Sets the number of seconds the dial buffer waits for digits after pressing
9 before assuming the dial string is complete. This value applies until DIALTIMERDIGITS have
been dialed. (Valid range = 2–30 seconds, default = 20 seconds)
set dialtime2={n}—Sets the number of seconds the dial buffer waits for digits after pressing
9 before assuming the dial string is complete. This value applies after DIALTIMERDIGITS have
been dialed. (Valid range = 2–30 seconds, default = 2 seconds)
set dndtime={n}—Sets the number of hours a standard phone or Modem/Fax port will remain
on Do Not Disturb. The DND state is cancelled when this timer expires. Setting a value of 0
disables this timer. (Valid range = 0–999 hours, default = 1 hour)