Air Intake / Vent System Options; Vent System Components Included With Boiler; Burnham Vent System And Air Intake System Components - Burnham Revolution Installation, Operating And Service Instructions

Gas- fired boiler
Hide thumbs Also See for Revolution:
Table of Contents

Advertisement

Table 1: Air Intake / Vent System Options
Option
Direct Vent (sealed combustion) with both the vent pipe and
1. Separate
air intake pipe terminating horizontally (through a sidewall)
Horizontal
with individual penetrations for the vent and air intake piping
and terminals.
Direct Vent (sealed combustion) with both the vent pipe and
2. Separate
air intake pipe terminating vertically (through the roof) with
Vertical
individual penetrations for the vent and air intake piping and
terminals.
Direct Vent (sealed combustion) with the vent pipe and air
3. Combination
intake pipe joining at a common terminal and terminating
horizontally (through a sidewall up to 15" thick) with only
Horizontal
one penetration.
Direct Vent (sealed combustion) with the vent pipe and air
4. Combination
intake pipe joining at a common terminal and terminating
Vertical
vertically (through the roof) with only one penetration.
Power Vent - Air used for combustion is provided from within
5. Indoor Air
the building.
6. PVC Air
Allows use of PVC pipe (4" Dia. S & D [thin wall] PVC) in lieu
of single wall metal pipe for air intake piping.
Intake
Table 3: Burnham Vent System and Air Intake System Components
Vent System Component
3" Dia. Pipe x 1 Ft
3" Dia. Pipe x 3 Ft
3" Dia. Pipe x 5 Ft
3" Dia. Pipe x Adjustable
3" Dia. 90° Elbow
3" Dia. 45° Elbow
3" Dia. Horizontal Drain Tee
3" Dia. Vertical Drain Tee
3" Single Wall Thimble
3" Double Wall Thimble
Description
Table : Vent System Components Included with Boiler
Vent System Components
Gasketed Vent Terminal Horizontal (RV3 - RV7)
Disc Air Intake - 3" (RV3 - RV4)
Disc Air Intake - 4" (RV5 - RV7)
Equivalent
Part Number
Feet of Pipe
8116296U
1
8116298U
3
8116300U
5
Equal to
8116319U
Installed Length
(1.06 TO 1.64)
8116294U
5
8116292U
5
8116302U
2
8116304U
---
8116116
8116115
---
Additional
Part
Vent Kit
Number
Required
See Table 2
No
6116062
Yes
(RV3-RV7)
61106012
Yes
(RV3-RV7)
61106014
Yes
(RV3-RV7)
61106008
(RV3-RV4)
Yes
61106009
(RV5-RV7)
6116054
Yes
(RV3-RV7)
Part
Number
8116234
6116045
6116044
Intake System
Components
(Parts by Others)
4" ID Pipe x 1 Ft
4" ID Pipe x 2 Ft
4" ID Pipe x 4 Ft
4" ID Pipe x 5 Ft
4" 90° Elbow
4" 45° Elbow
* Equivalent Feet of Pipe Based on
Standard 4" Smoke Pipe Design
Installation
Drawing and
Specification
(Section)
F.
G.
H
I.
J.
K.
Equivalent
Feet of Pipe *
1
2
4
5
5
5
9