COMPONENT ACCESS (cont)
MASTER POWER SWITCH (cont)
If continuity is not present as described, replace the
switch.
Removal and Replacement:
1. Disconnect the brewer from the power source.
2. Disconnect the wires from the power switch.
3. Remove the switch mounting screws from the
under the base.
4. Install new switch in trunk with the two 6-32 x ¼˝
mounting screws.
5. Connect wires to the switch terminals.
SH SERVER TIMER SETTING
Timer may be set to the OFF position as shown
on Tag (Fig 15) to prevent the LED on the front of
the server from flashing, or one of nine various set-
tings to flash the LED after Timer has expired. For
instance, setting Timer on position 5 will flash the
LED after 120 minutes. Server must be docked on a
SH Brewer or SH Server Stand to engage Timer.
INSTRUCTIONS:
• Empty all contents and turn server upside down.
• Remove two screws (Fig 14) securing bottom
cover to server, remove bottom cover from server.
• Refer to the Timer Setting Tag (Fig 15) to deter-
mine the desired timer setting number.
• Using a small flat blade screwdriver, set the Timer
to the corresponding number (Fig 16).
• Install the bottom cover on server and secure with
screws.
FIG 14 REMOVE BOTTOM COVER
FIG 15 TIMER & TAG
FIG 16 SETTING TIMER