Bunn BrewWise DBC Service Manual page 43

With smart funnel
Table of Contents

Advertisement

Wire as shown for 3 phase. For single
phase operation, move red wire in
terminal block into cell with black wire;
apply power across L1 & N.
FUNNEL SENSOR
VIO
WHI/VIO
WHI
PNK
BLK
TEMP PROBE
WATER LEVEL
PROBE
GRN
Switch Unit Assembly Codes
A1
Brew
C2
A2
On/Off
C3
B1
"Hidden" Left
D1
B2
"Hidden" Right
D2
C1
Large Batch
D3
LED's
L1
Large Batch LED
L2
Medium Batch LED
L3
Small Batch LED
L4
On/Off LED
SCHEMATIC WIRING DIAGRAM
SINGLE TF DBC, CE
L1
L2
L3
TERMINAL BLOCK
L1
L2
L3
GRN
EMI FILTER
L1
L2
L3
BLK
BLU
BRN
1
2
LIMIT THERMOSTAT (1/2)
CONTROL PC BOARD
Medium Batch
Small Batch
"Digital" Left Hidden Button
"Brewer" Center Hidden Button
"Control" Right Hidden Button
Page 43
3 PHASE W/NEUTRAL
N
- LINE
N
- LOAD
N
RED
2.2uF
BLK
RED
CONTACTOR
RED/BLK
RED
BRN
BRN
BLU
BLU
BLK
BLK-14
SWITCH UNIT ASSEMBLY
RED/BLK
VIO
WHI/GRN
GRY
YEL
BLK
RED
BRN/WHI
BRN/BLK
400-415 VOLT A.C.
PHASE TO PHASE,
230 VOLTS AC
PHASE TO NEUTRAL
3 PHASE 50/60 HZ
36883.0003A 02/07 © 2007 Bunn-O-Matic Corporation
HEATER
HEATER
#1
#2
1
3
2
4
HEATER
LIMIT
#3
TANK LID ASEMBLY
4
3
THERMOSTAT (1/2)
TANK HEATER #3
TANK HEATER #2
TANK HEATER #1
REFILL
SOL
BYPASS
SOL
BREW
SOL
BREWER
RED
RED
ON/OFF
SWITCH
N.C.
OVERFLOW
PROTECTION SWITCH
SOL
FUNNEL LOCK
RED
RED
RED
RED
RED
RED
RED
41746 112008