Bunn BrewWise DBC Service Manual page 32

With smart funnel
Table of Contents

Advertisement

LIMIT THERMOSTAT
BLK-14
FUNNEL SENSOR
VIO
WHI/VIO
TEMP
WATER LEVEL
WHI/RED
PROBE
PROBE
120/208 VOLT A.C. OR
120/240 VOLT A.C.
RED
3 WIRE + GND
SINGLE PHASE
32043.0005B 02/07 ©2006 BUNN-O-MATIC CORPORATION
SCHEMATIC WIRING DIAGRAM
SINGLE SH DBC with SMART FUNNEL
(With Audible Alarm)
BLK-14
SHIELD
CONTROL PC BOARD
WHI
PNK
BLK
BLK
GRN
BLK
WHI
SERVER
TRANSFORMER
BLU/BLK
4
AMP
24VDC
BLU/BLK
+
BLK
AC
RECTIFIER
+
AC
White Strip-Tac Plus
Black Ink
Finished Size: 7" x 9"
~75% Reduction
Page 32
MODELS WITH MAIN ON/OFF SWITCH ONLY
BLK-14
BLK-14
RED-14
RED-14
TRIAC
MT 1 BLU -14
MT2
SWITCH UNIT ASSY
BLK
VIO
SOL
WHI/GRN
GRY
BREW
SOL
WHI/VIO
TAN
YEL
BLK
WHI
BRN/WHI
BRN/BLK
Touch Switch Assembly Codes
A1
Brew
A2
On/Off
B1
"Hidden" Left
B2
"Hidden" Right
C1
Large Batch
C2
Medium Batch
C3
Small Batch
D1
"Digital" Left Hidden Button
D2
"Brewer" Center Hidden Button
D3
"Control" Right Hidden Button
L1
N
GRN
BLK-14
RED-14
TANK HEATER
AUDIBLE
ALARM
(FRESHNESS)
WHI
WHI
REFILL
BYPASS
WHI
SOL
WHI
RED
RED
N.C.
OVERFLOW
PROTECTION SWITCH
WHI
SOL
FUNNEL LOCK
(OPTIONAL)
WHI
LED's
L1
Large Batch LED
L2
Medium Batch LED
L3
Small Batch LED
L4
On/Off LED
41746 112008
L2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brewwise dbc series

Table of Contents