Specifications - Lincoln Electric POWER MIG 210 MP Operator's Manual

Hide thumbs Also See for POWER MIG 210 MP:
Table of Contents

Advertisement

Available languages

Available languages

POWER MIG
®
210 MP
DESIGN

SPECIFICATIONS

POWER SOURCES - INPUT VOLTAGE AND CURRENT
DUTY CYCLE
INPUT VOLTAGE INPUT AMPERES
(OUTPUT)
25%
230
(200A / 24V)
40%
120
(100A / 19V)
POWER SOURCES -
RECOMMENDED INPUT WIRE AND FUSE SIZES
VOLTAGE/
INPUT
FUSE (SUPER
PHASE
AMPERES
LAG) OR
FREQUENCY
EFFECTIVE
BREAKER
SIZE
230/1/60
14.7
120/1/60
15
PHYSICAL DIMENSIONS
MODEL
HEIGHT
WIDTH
K3963-1
14.00IN
10.75IN
(356MM)
(273MM)
1 Cord and Fuse Sizes based upon the U.S. National Electric Code and maximum output
2 Also called 'inverse time' or 'thermal/magnetic' circuit breakers; circuit breakers that have a
delay in tripping action that decreases as the magnitude of current increases.
IDLE AMPS
MAX
27A
.55A
21.5A
.55A
1
TYPE 75C COPPER WIRE IN
CONDUIT AWG (IEC) SIZES
40C (104°F) AMBIENT
2
40
12
20
12
DEPTH
WEIGHT
19.03IN
40 LBS
(484MM)
18 KG
WELDING PROCESSES
PROCESS
ELECTRODE DIAMETER RANGE
GMAW
.025-.035"
(0.6-1.0MM)
FCAW
.030-.045"
(0.8-1.2MM)
GTAW
1/16, 3/32 IN
(1.59, 2.38MM)
SMAW
3/32, 1/8, 5/32 IN
(2.38, 3.18, 3.97MM)
9
DESIGN
OUTPUT RANGE
WIRE FEED
(AMPERES)
SPEED RANGE
20-220
50-500 IPM
20-220
50-500 IPM
20-175
NA
20-175
NA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents