1. Remove all external packaging that is protecting top portion of unit.
2. Remove unit from shipping container while in the upright position. The unit can be lifted out of the
carton by grasping under the conveyor on each side of the appliance. Please remove the plastic
bag.
3. Remove all internal packaging to the unit.
inside the tunnel oven between the top heaters and the conveyor.
conveyor trays. Remove tape from extrusion corners. Remove tape from deflecting curtains
located just above entrance and exit of conveyor.
4. Visually inspect all external and internal portions of unit for damage.
top white ceramic elements located inside the oven tunnel after removal of urethane
supports.
To inspect these white ceramic elements, use a small mirror held under each element to
Important: The Ceramic elements are fragile and will break under
detect cracks.
stress. Do not twist, pull, push, or otherwise subject the white ceramic elements to
stress.
5. Wipe down the exterior of the unit using a damp cloth with warm water. Do not use abrasive pads or
cleaners as they will damage the stainless steel surface and high temperature plastic.
NOTE: DO NOT USE CLEANERS OF ANY KIND ON THE WHITE CERAMIC HEATERS.
6. Remove four feet from box and install into threaded nuts located at the four corners underside of the
left and right housings; Also remove conveyor extension tray(s). Conveyor extensions should be
hung off end of conveyor frame. As our standard, Model XWAV 1417A will only have one extension
intended for the exit end.
7. Place unit in operating location.
Note: Ambient Conditions - Make sure that the operating location is in an area where the
ambient temperature is held constant (minimum 70°F). Please avoid areas such as near
exhaust fans and air conditioning ducts.
Warning: Operating environment
Ensure that operation location is at a reasonable distance from combustible walls and materials
otherwise combustion or discoloration could occur. Stand-off/Air-divider located on rear panel is
important in maintaining proper division of inlet and exhaust air flow - If removed it could result in
improper functioning of unit and MAY cause personal injury and WILL void your warranty.
Caution: Operating environment
Place unit on a stable, level counter at a convenient height for use. Turn the adjustable feet so
that unit is level to countertop. The top of the unit is not intended for use a shelf. Materials
placed there are at risk for fire.
8. Before plugging unit into wall, make sure that the switch is in the off position.
9. Warning: Ensure no hands, tools or parts or other unintended items are located on the conveyor
as injury will result when unit is turned on.
10. Plug unit into grounded electrical outlet with correct voltage, and plug configuration.
Warning: Using any receptacle that is not designed to match the attached cord and plug MAY
cause personal injury and WILL void your warranty.