Grundig PS 8710 Instructions Manual

Grundig PS 8710 Instructions Manual

Grundig body analyzer scale

Advertisement

02PS8710_en
27.10.2009
BODY ANALYZER SCALE PS 8710
Safety
Please note the following instructions when using
the appliance.
The appliance is designed for domestic use
7
only.
Do not use the appliance on a carpet or rug.
7
Always use the appliance on an even, hard
7
floor. This ensures more exact measurement
readings.
Stand on the section of the glass surface sup-
7
ported with a silver frame and keep at least
2 cm away from the edge. Be careful when
doing this.
Step onto the appliance carefully with only the
7
left foot or the right foot, placing it on the
section of the glass surface supported by the
silver frame. Make sure you keep a minimum
of 2 cm away from the edge. Then place your
other foot on and position it in the same way
on the other side of the glass surface. Be very
careful when doing this.
Position your bodyweight in the middle of the
7
appliance before you take one foot off it.
Always make sure the appliance cannot tip
over, as there is a risk of injury.
Never use the appliance outdoors.
7
Do not use the appliance during a thunder-
7
storm.
Do not continue to use the appliance if a mal-
7
function occurs.
Do not continue to use the appliance if there
7
are any cracks or chips in the glass plate.
Do not place any objects on the glass surface.
7
14
ENGLISH
14:04 Uhr
Seite 14
___________________
Never jump on or off the appliance.
7
If the appliance is being used in the bathroom,
7
on no account should it come into contact with
water.
Do not immerse the appliance in water.
7
Do not expose the appliance to direct sunlight,
7
high temperatures or constantly high humidity.
Keep the appliance away from children.
7
Never use the appliance if it is visibly damaged.
7
Do not open the appliance under any circum-
7
stances. No warranty claims are accepted for
damage resulting from improper handling.
Caution
The appliance may not be used by the following
groups of people:
Pregnant women and children under the age
7
of 18 (the exact body mass index cannot be
determined in these cases).
The appliance works out your body mass index
7
using BIA (Bioelectrical Impedance Analysis).
This sends a harmless signal through the body.
The appliance is not suitable for people who
are fitted with a pacemaker or with any other
medical implants. If in doubt, seek medical
advice.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PS 8710 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Grundig PS 8710

  • Page 1 02PS8710_en 27.10.2009 14:04 Uhr Seite 14 BODY ANALYZER SCALE PS 8710 ___________________ Safety Please note the following instructions when using Never jump on or off the appliance. the appliance. If the appliance is being used in the bathroom, The appliance is designed for domestic use on no account should it come into contact with only.
  • Page 2: Packing Contents

    Metal housing and thumb grips Caution (measurements are calculated here). The PS 8710 is a product for your well-being. It is not a medical product. No medical recom- Control unit back panel and mendations can be made on the basis of its accessories use or of the results displayed.
  • Page 3: Power Supply

    02PS8710_en 27.10.2009 14:04 Uhr Seite 16 BODY ANALYZER SCALE PS 8710 ___________________ Power supply If the batteries are running down (approx. 2.3 V), a battery symbol appears in the dis- The scale operates with four AAA batteries play. Insert new batteries immediately.
  • Page 4 02PS8710_en 27.10.2009 14:04 Uhr Seite 17 BODY ANALYZER SCALE PS 8710 ___________________ Activate the scale by tapping lightly on the Note If the following display appears just after glass surface with your foot once. weighing, it does not mean there is a mal- –...
  • Page 5 02PS8710_en 27.10.2009 14:04 Uhr Seite 18 BODY ANALYZER SCALE PS 8710 ___________________ Press the »SET« button. Hold the detached control unit with both – Display: the symbol of the woman’s head hands. flashes. Switch on the control unit and scale by press- ing the »ON/OFF«...
  • Page 6 02PS8710_en 27.10.2009 14:04 Uhr Seite 19 BODY ANALYZER SCALE PS 8710 ___________________ Press the »SET« button to confirm. Performing the analysis – Display: the »A 1« user specification flashes. The procedure described here uses parameter 01 as an example. Place the scale on a smooth flat surface.
  • Page 7: Notes On Measurements

    02PS8710_en 27.10.2009 14:04 Uhr Seite 20 BODY ANALYZER SCALE PS 8710 ___________________ While »0.0 kg« is showing in the display, care- TBM – total body mass (bone mass, fully step onto the glass surface of the scale muscle, calories): holding the control unit in both hands.
  • Page 8 02PS8710_en 27.10.2009 14:04 Uhr Seite 21 BODY ANALYZER SCALE PS 8710 ___________________ The following guidelines for body fat mass and Muscle composition total body water apply for men: The following guidelines roughly apply to the muscle composition for men: Body fat...
  • Page 9: Mounting The Control Unit On The Wall

    02PS8710_en 27.10.2009 14:04 Uhr Seite 22 BODY ANALYZER SCALE PS 8710 ___________________ Notes on operating and Mounting the control unit on the cleaning wall The maximum load of the scale is 180 kg. The Fix the bracket on the wall making sure the following appears in the display if the maxi- raised magnet strip is facing outwards.
  • Page 10: Environmental Note

    02PS8710_en 27.10.2009 14:04 Uhr Seite 23 BODY ANALYZER SCALE PS 8710 ___________________ Environmental note Technical data This product fulfils the European This product has been made from high-quality directive 2004/108/EC. parts and materials which can be re-used and recycled. Power supply Therefore, do not throw the product away with 3 x AAA batteries, 4.5 V (control unit)

Table of Contents