Async Test - Toshiba 430CDT Maintenance Manual

430 series
Hide thumbs Also See for 430CDT:
Table of Contents

Advertisement

3.10 Async Test

To execute the Async Test, select 7 from the DIAGNOSTIC TEST MENU, press Enter and
follow the directions displayed on the screen. The async test contains eight subtests that test
the asynchronous communication functions. Move the highlight bar to the subtest you want
to execute and press Enter.
Subtests 01 through 08 require the following data format:
Method:
Speed:
Data:
Data pattern:
The following message will appear at the bottom of the screen when subtests 01, 03, 04, 06,
07 and 08 are selected:
Channel#1 = XXXXh
Channel#2 = XXXXh
Channel#3 = XXXXh
Select the Channel number (1/2/3)
The serial I/O port address is specified by the XXXXh number. Select the serial port channel
number, and press Enter to start the subtest.
Subtest 01
Wraparound (board)
NOTE: To execute this subtest an RS-232-C wraparound connector
(34M741621G01) must be connected to the RS-232-C port. The RS-232-C
wraparound connector wiring diagram is described in Appendix F.
This subtest checks the data send/receive function through the wraparound
connector.
Subtest 02
Board (#1) <=> board (#2)
NOTE: To execute this subtest an RS-232-C cable (9-pin to 9-pin) must be
connected to boards 1 and 2. The RS-232-C direct cable wiring diagram is
described in Appendix F.
This subtest checks the data send/receive function through the RS-232-C
direct cable.
3-22
Asynchronous
9600BPS (Subtests 01 to 05)
38400BPS (Subtests 06 to 08)
8 bits and one parity bit (EVEN)
20h to 7Eh
430 Series

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

430cds

Table of Contents