Program Switches:
1. Unplug the brewer and let it cool down before proceeding.
3. Remove the left rear cover.
4. Flip the dip switches as needed.
NOTE: All switches are turned OFF from factory.
KEY #
4. High altitude
3. Energy Save
2. Brew lockout
1. Program lockout
SWITCH SETTINGS
FUNCTION - OFF
Set temp 200°F (93°C)
No energy save mode
Brew @ any temp
Programming allowed
FIG 18A
OFF
Page 18
FUNCTION - ON
Set temp 190°F (87.8°C)
Drops to 140°F (60°C) @ 6 hours/OFF @ 26h
Only brews when it indicates ready
All programming locked out
FIG 18B
ON
40410 092407