Download Print this page

Troubleshooting - Rotel RA-1062 User Manual

Stereo integrated amplifier
Hide thumbs Also See for RA-1062:

Advertisement

Troubleshooting

Most difficulties in audio systems are the re-
sult of incorrect connections, or improper
control settings. If you encounter problems,
isolate the area of the difficulty, check the
control settings, determine the cause of the fault
and make the necessary changes. If you are
unable to get sound from the RA-1062 refer
to the suggestions for the following conditions:
Power Indicator Is Not Lit
The power indicator should be lit whenever
the RA-1062 is plugged into the wall power
outlet and the POWER switch is pushed in. If
it does not light, test the power outlet with
another electrical device, such as a lamp. Be
sure the power outlet being used is not con-
trolled by a switch that has been turned off.
Fuse Replacement
If another electrical device works when plugged
into the power outlet, but the power indica-
tor still will not light when the RA-1062 is
plugged into the wall outlet, it indicates that
the internal power fuse may have blown. If
you believe this has happened, contact your
authorized Rotel dealer to get the fuse replaced.
No Sound
Check the signal source to see if it is functioning
properly. Make sure the cables from the sig-
nal source to the RA-1062 inputs are connected
properly. Be sure the LISTENING selector is
set to the proper input. Be sure the SPEAK-
ERS selector is set to the proper position. Check
the wiring between the RA-1062 and the
speakers.
9
Specifications
Continuous Power Output
Total Harmonic Distortion (20Hz-20kHz)
Intermodulation Distortion (60 Hz : 7 kHz, 4:1) < 0.03% at rated power, 1/2 power or 1 watt
Frequency Response
Phono Input
Line Level Inputs
Damping Factor (20-20,000 Hz, 8 ohms)
Line Input Sensitivity / Impedance
Line Input Overload
Phono (MM) Sensitivity / Impedance
Input (Phono) Overload
Preamplifier Output / Impedance
Signal to Noise Ratio (IHF "A" weighted)
Power Requirements
USA:
EC:
Power Consumption
Dimensions (W x H x D)
Front Panel Height
Weight (net)
All specifications are accurate at the time of printing.
Rotel reserves the right to make improvements without notice.
Rotel and the Rotel HiFi logo are registered trademarks of The Rotel Co, Ltd., Tokyo, Japan.
60 watts/channel (20-20 kHz, < 0.03%, 8 ohms)
< 0.03% at rated power, 1/2 power, or 1 watt
20Hz-15kHz, ±0.2dB
10Hz-100kHz, +1, –3dB
150
160 mV / 24 kOhms
5 V
2.4mV /47 kohms
170 mV
1V / 470 ohms
>95 dB
115 Volts, 60 Hz
230 Volts, 50 Hz
300 Watts
430 x 92 x 355 mm
5
17 x 5
/
x 14 inches
8
3
80mm / 3
/
inches
16
7.8 kg, 17.2 lbs.
English