FILTER CARE
FILTER CARE
FILTER CARE
FILTER CARE
Inspect the air filter(s) at least once a month. If they are dirty, wash
reusable filters with a mild detergent per manufacturer's recommenda-
tions. Replace disposable filters with new filters.
PROBLEM
1. Thermostat for proper settings.
No Heat
2. Circuit breakers and fuses.
or
3. Check outdoor unit for dirty coil (Cooling).
Cooling
4. Indoor unit for dirty filter (Heating).
Wet on Floor
Condensate drain and "P" trap
or in Furnace
CLEARANCES
CLEARANCES
CLEARANCES
CLEARANCES
The minimum clearances shown below must be maintained should any
patio or yard improvements be done around the outdoor unit.
• Top 48"
• Sides 12"
• Access 24"
POWER INTERRUPTION
POWER INTERRUPTION
POWER INTERRUPTION
POWER INTERRUPTION
When ice, snow, wind storms, etc. disrupt electrical power supply to
your house, proceed as follows:
1.
Switch thermostat to OFF position.
2.
Do not switch to cooling or auto until electrical power has been re-
established for 8 hours if the power was off more than 8 hours.
Unitary Products Group
TROUBLESHOOTING GUIDE
CHECK
Install the clean filters with "air flow" arrow in the same direction as the
air flow in your duct. Filters should be clean to assure maximum effi-
ciency and adequate air circulation. Drapes, furniture or other obstruc-
tions blocking your supply and return air grilles will also decrease
efficiency.
OUTDOOR UNIT FINISH
OUTDOOR UNIT FINISH
OUTDOOR UNIT FINISH
OUTDOOR UNIT FINISH
If you wish to maintain the finish of the outdoor unit, it can be polished
with car wax. It is recommended the unit be cleaned with soap and
water prior to waxing.
ACTION TO TAKE
Set thermostat to proper setting.
Reset circuit breakers - Replace blown fuses.
Clean coil, see "COIL CARE" section.
Clean or replace, see "FILTER CARE" section.
Remove blockage, usually mold or fungus.
SERVICE CALLS
SERVICE CALLS
SERVICE CALLS
SERVICE CALLS
There are a few instances where you can avoid unnecessary service
calls. (See Troubleshooting Guide above). Some models provide fault
codes. The flashing light on the system thermostat is capable of provid-
ing you with time and money saving information. The fault code num-
bers listed can be handled by taking the corrective action indicated. Call
qualified service person if displaying fault code numbers not listed.
PARTS INFORMATION
PARTS INFORMATION
PARTS INFORMATION
PARTS INFORMATION
Replacement parts are available from local contractor/dealers or the
nearest distribution center.