PROXIMITY TO SIDE CABINET INSTALLATION
1.
Range / Range tops may be installed directly adjacent to existing 36" high base cabinets.
IMPORTANT-the top grate support MUST be 3/8" above the adjacent base cabinet countertop.
This may be accomplished by raising the unit, ( using the adjustment spindles on the range legs)
or ( using shims for the range top).
2.
The range / range top CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appli-
ances, or other side vertical surfaces above 36" high. There must be a minimum of 6" side clearance
from the range to such combustible surfaces above the 36" counter height.
3.
Within the 6"side clearance to combustible vertical surfaces above 36", the maximum wall cabinet
depth must be 13" and wall cabinets within this 6"side clearance must be 18" above the 36" high
countertop.
4.
Wall cabinets above the range / range top must be a minimum of 36" above the cooking surface for
the full width of the range / range top.