ELECTRICAL CONNECTIONS WITH CONDUIT
Use ½" trade size conduit with a conduit clamp, 12 AWG /600 volt
copper conductor colored red for line # 1 and black for line # 2 and
14 AWG /600 volt copper conductor colored white for neutral with
closed loop terminals marked for use with ranges. Where local codes
do not permit grounding through neutral, use a green 12 AWG copper
conductor as directed in the 4 - wire connector directions. The conduit
must be secured to the range with the strain relief bracket. The electrical
connection is made at the terminal block which is located behind the access
door on the back of the range.
3 - Wire Power Connection
1.
Remove access door.
2.
Remove strain relief mounting angle and reattach as shown.
3.
Feed ½" trade size conduit through the hole in the bottom
of the range back and secure to the strain relief bracket with
a conduit clamp.
4.
Feed line #1 (red 12 AWG / 600v copper conductor), line #2
(black 12 AWG / 600v copper conductor), and neutral (white
14 AWG / 600v copper conductor) through conduit and
attach closed loop terminals marked for use with ranges.
5.
Remove 3 mounting screws and attach line #1 (red) to left
terminal, line #2 (black) to the right terminal, and the neutral
wire (white) to the center terminal.
6.
Reattach the access door.
4 - Wire Power Connector
1.
Remove access door.
2.
Remove strain relief mounting angle and reattach as shown.
3.
Feed 11/2" trade size conduit through the hole in the bottom
of the range back and secure to the strain relief bracket withe
a conduit clamp.
4.
Feed line #1 (red 12 AWG / 600v copper conductor), line #2
(black 12 AWG / 600v copper conductor), neutral (white
14 AWG / 600v copper conductor), and a grounding wire
(green 12 AWG copper conductor) through conduit and attach
closed loop terminals marked for use with ranges. (Terminal is
not required on grounding wire if used with ground washer).
5.
Remove 3 mounting screws and green grounding screw. Cut-
off and discard ground strap. Attack line #1 (red) to the left
terminal, line #2 (black) to the right terminal, the neutral wire
(white) to the center terminal and the copper ground wire to the
green grounding screw using the ground washer.
6.
Reattach the access door.
43