Connecting The Zvr-410; Camera Number Assignment - ZoneVu ZVR-410 User Manual

Telemetry receiver
Table of Contents

Advertisement

¡
¢
¡
£
¤
¡
¥
¦
§
¨
¨
¤
¡

2.2 CONNECTING THE ZVR-410

Connect up the ZVR-410 in accordance with the accompanying wiring diagram, paying special
attention to the maximum ratings and the notes below.
1. The ZVR-410 MUST be earthed at the AC input supply terminal.
2. NEVER run cables directly under the PCB as this may interfere with the operation of the
Telemetry ZVR-410 and other camera head equipment.
3. ALWAYS use Screened cables for low voltage and signal cables ensuring the screen is
connected to 0V or Earth.
4. AVOID looming cables of differing characteristics together E.G. Video cables with cables
carrying mains power.
5. If the ZVR-410 is to be operated over twisted pair cable ensure the screen is connected to 0V.
6. The maximum cable run for Twisted Pair is typically 2Km.
7. The maximum cable run for VICTA is typically 350m for RG59 and 750m for RG11. The cable
run must be unbroken.
8. The maximum number of Telemetry Receivers that can be connected to a driver output is 32.
9. The cable used to wire the secondary of the transformer should be a minimum of 0-5mm

2.3 CAMERA NUMBER ASSIGNMENT

When operating the ZVR-410 using RS-422 telemetry, a receiver address must be set up which
corresponds to the connected matrix output. The ZVR-410 receiver address can be set in the range 1-
299. If operating the ZVR-410 over Meyertech VICTA coax telemetry, no receiver address is
necessary.
To set the ZVR-410 receiver address:
1. If the camera address is in the hundreds fit the appropriate links +100 or +200. Only one of
these links should be fitted.
2. Set the tens switch.
3. Set the units switch.
©