Installation; Installation Safety Instructions; Position The Operator; Important Installation Instructions - Chamberlain Grifco CG3800 Instruction Manual

Light duty commercial door operator
Table of Contents

Advertisement

IMPORTANT INSTALLATION INSTRUCTIONS

To reduce the risk of SEVERE INJURY or
1.READ AND FOLLOW ALL INSTALLATION
WARNINGS AND INSTRUCTIONS.
2.Install door operator ONLY on properly balanced
and lubricated the door. An improperly balanced
door may not reverse when required and could
result in SEVERE INJURY or DEATH.
3.ALL repairs to cables, spring assemblies and
other hardware MUST be made by a trained door
systems technician BEFORE installing operator.
4.Disable ALL locks and remove ALL ropes
connected to the door BEFORE installing
operator to avoid entanglement.
5 Mount emergency release handle no higher than
1.8m above floor.
6.NEVER connect the door operator to power
source until instructed to do so.
INSTALLATION STEP 1
Position the Opener
NOTE: For additional mounting options see accessories
page.
1. Close the door completely.
2. Slide the operator with collar over the end of the torsion
bar. Ensure that the collar does not touch the bearing
plate. Check to make sure the mounting bracket is
located on a solid surface such as wood, concrete or
door/flag bracket. Snug collar screws to help assure
proper alignment of operator. Mark the bracket holes. It
may be necessary to cut the torsion bar if it is too long
or damaged.
3. Loosen collar screws from torsion bar and remove the
operator. Drill 5mm (3/16") pilot holes at the marked
locations. Drill through steel plate if needed.
4. Reinstall the operator by sliding the collar over the
torsion bar until pilot holes align with bracket. Securely
tighten collar screws that attach to the torsion bar to
16Nm-19Nm of torque. Securely tighten both set screws
firmly, without damaging the motor unit.
5. Fasten bracket securely with 14-10x1-7/8" screws.
Tighten all mounting bracket hardware.
NOTE: The motor unit does not have to be flush to wall.
6. Use a staple to secure the antenna wire to prevent
antenna from being entangled in a door roller.

INSTALLATION

WARNING
WARNING
7.NEVER wear watches, rings or loose clothing
while installing or servicing operator. They could
be caught in the door or operator mechanisms.
8.Install wall-mounted door control:
• within sight of the door.
• out of reach of children at minimum operator of
1.5 m.
• away from ALL moving parts of the door.
9.Place entrapment warning label on wall next to
door control.
10.Place manual release/safety reverse test label in
plain view on inside of the door.
11.Upon completion of installation, test safety
reversal system. Door MUST reverse on contact
with a 40mm (1 1/2") high object (or a 2x4 laid
flat) on the floor.
To prevent possible SERIOUS INJURY or DEATH:
• Concrete anchors MUST be used if mounting bracket
into masonry.
• NEVER try to loosen, move or adjust the door,
springs, cables, pulleys, brackets or their hardware,
ALL of which are under EXTREME tension.
• ALWAYS call a trained door systems technician if the
door binds, sticks or is out of balance. An unbalanced
door might not reverse when required.
• Operator MUST be mounted at a right angle to the
torsion bar to avoid premature wear on the collar.
Staple
7
DEATH:
Torsion Bar

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents