Maintenance - Panasonic HIT Double Photovoltaic modules General Installation Manual

Advertisement

General Installation Manual
© Apr 2012, SANYO Electric Co., Ltd. All Rights Reserved
the same series is forced to flow
through the shaded area.
cause undesirable heating to occur.
The use of a diode to bypass the
shaded area can minimize both heating
and array current reduction.
Modules are equipped with four (4)
factory installed bypass diodes. The
factory-installed diodes provide proper
circuit protection for the systems within
the specified system voltage, so that
you do not need any other additional
bypass diodes.

MAINTENANCE

Some maintenance is recommended to
maintain optimal output performance of
the HIT Double solar modules.
When a module's front or back surface
becomes dirty, power output is reduced.
It is recommended to clean the front
surface of the module with water and a
soft cloth or sponge, twice or more per
year. It is recommended to clean the
back surface as needed.
A mild non-abrasive detergent may be
applied for persistent dirt.
It is also recommended to inspect the
electrical and mechanical connections
annually.
If you need electrical or mechanical
inspection
or
maintenance, it
recommended to have a licensed
authorized professional carry out the
inspection or maintenance to avoid the
hazards of electric shock or injury.