Panasonic HIT Power 240S Series General Installation Manual

Panasonic HIT Power 240S Series General Installation Manual

Hide thumbs Also See for HIT Power 240S Series:

Advertisement

General Installation Manual
Photovoltaic Module HIT
HIT Power 240S series
HIT Power 235S series
HIT Power 230S series
Thank you for choosing Panasonic HIT
read this manual completely before installation
or use of Panasonic PV(photovoltaic) modules.
With
proper
operation
and
Panasonic HIT
®
will provide you with clean,
renewable solar electricity for many years. This
manual
contains
important
maintenance and safety information. The word
"module" as used in this manual refers to one
or more PV modules.
Retain this manual for
future reference. The module is considered to
be in compliance with UL 1703 only when the
module is mounted in the manner specified by
the mounting instructions below.
SANYO is part of the Panasonic Group and is
in charge of the manufacturing process for
®
Panasonic HIT
.
VBHNxxxSA series
®
Model No.
HIT Power 240S
VBHN240SA11 and 11B
HIT Power 235S
VBHN235SA11 and 11B
HIT Power 230S
®
. Please
VBHN230SA11 and 11B
maintenance,
installation,
Contents
Please read before installation
 Note on Specifications
 General
Bypass Diodes
Customer Services
"HIT" is a registered trademark of Panasonic
Group.
Other product and service names listed in this
manual are trademarks or registered trademarks
of their respective companies.
1
:3
:3
:3
:3
:3
:4
:4
:5
:5
:5
:5
:5
:5
:5
:6
:6
:8
:8
:8
:8
:8
:8
:8

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic HIT Power 240S Series

  • Page 1: Table Of Contents

     Module Wiring the mounting instructions below.  Array Wiring  Earth Ground Wiring SANYO is part of the Panasonic Group and is  Grounding Locations in charge of the manufacturing process for  Grounding Methods ®...
  • Page 2: Grounding

    Edition Revision Date Revised Item Revised Content New Edition 2013.4.19 (1) Addition of System Fire Class Rating (1) System Fire Class Rating (2) Explanation of trademark Edition 2015.3.18 (2) Trademark (3) According to UL1703 Edition 3 (3) Front cover, Grounding –...
  • Page 3: Safety Precautions

     Completely ground all modules. installing or using your Panasonic PV modules. inspection requirements, which should be  Do not disassemble a module, attempt any This section contains important electrical and followed. repair, open the junction box cover, nor mechanical specifications.
  • Page 4: Notes On Installation :4

    0.12”(3 mm) or more (11mm)  Material: Aluminum Alloy (6005-T5, 0.2” 6105-T5, 6061-T6) (5mm)  Panasonic does not provide a warranty for clamps. module warranty Panasonic provides shall be voided if clamps selected M8 Bolt customer improper M8 Nut material or size...
  • Page 5: Specifications

    IEC 60904-3. Note: At the appropriate FUSE for each series string or only at the locations marked in this manual time of shipment, Panasonic guarantees the each module. (see grounding methods below). ...
  • Page 6: Grounding Locations :6

    No.10 (0.190’‘ diameter (4.83mm)).   Lay-in lugs or grounding clips can be used used grounding connections This method requires a minimum number of to ground Panasonic PV modules. Both accordance with instructions provided threads-per-inch to achieve an adequate methods explained below, please with the module.
  • Page 7: Module Terminations :8

    A junction box as a terminal enclosure is  Contact your Panasonic Authorized instructions previous section regarding equipped for electrical connections. Representative for proper diode type, if it is using bolts and nuts with larger grounding...
  • Page 8: Disclaimer Of Liability

     The return of any modules will not be accepted by Panasonic unless prior written authorization has been given by Panasonic.  As part of Panasonic’s policy of continuous improvement, Panasonic reserves the right Cable Connector Plug Option:...
  • Page 9 Glass Figure 3.2 (Method 1) Grounding method using self-tapping machine screw Backsheet Frame (Longer side) Note: the smaller ground holes illustrated in Figure 3.1. Grounding hole *If using a brass cup washer, a flat (0.165’‘ diameter (4.2 mm) ) washer must be inserted between the cup washer and module frame, and the flat washer diameter must be greater *Flat washer (Stainless steel)
  • Page 10 Figure 3.4 Glass Frame (Longer side) Grounding method Backsheet Using self-tapping machine screw Note: smaller ground holes illustrated in Figure 3.1. Grounding hole Select a grounding the following lug. (0.165” diameter (4.2mm)) ILSCO GBL-4DBT, Star washer (Stainless steel) Burndy CL501TN Thickness: not less than 0.02”...
  • Page 11 Figure 3.6 Grounding method Frame (Longer side) Using Grounding Clip with self-tapping Glass machine screw Backsheet Note: the smaller ground holes illustrated in Figure 3.1. Grounding Clip Assemblies: Tyco Grounding hole Electronics 1954381-1. (0.165” diameter (4.2mm)) Self-tapping machine screw (Stainless steel) Length (not less than 0.47’‘(12 mm) not more than 0.78’‘(20 mm))
  • Page 12 SPECIFICATIONS Electrical Specifications Model HIT Power 240S HIT Power 235S HIT Power 230S VBHN240SA11 VBHN235SA11 VBHN230SA11 VBHN240SA11B VBHN235SA11B VBHN230SA11B Cell Number in Series Rated Power, Watts (Pmax) Maximum Power Voltage (Vpm) 43.7 43.0 42.3 Maximum Power Current (Ipm) 5.51 5.48 5.45 Open Circuit Voltage (Voc) 52.4...

Table of Contents