Xtream HW2765HAD Operation Manual page 29

Diesel hot water pressure washer
Table of Contents

Advertisement

troubleshooting
SYMPTOM
Burner will not ignite
Burner runs erratically.
Burner runs, but will 
not heat.
Burner discharges 
white smoke.
Burner discharges 
black smoke.
PROBABLE CAUSE
Ignition module
Ignition electrodes 
damaged or worn.
No voltage
Pressure switch override.
High limit switch override.
Improper burner air 
adjustment.
Fuel solenoid valve failure.
Water in the fuel oil.
Dirty fuel filter/water 
separator.
Dirty fuel nozzle.
Fuel pickup screen 
obstructed. 
Improper air adjustment 
setting.
Fuel pump malfunctioning.
Poor or improper fuel 
supply.
Low fuel pump pressure.
Dirty fuel nozzle.
Improper air adjustment 
setting.
Scale build up in heat 
exchanger coil.
Low on fuel.
Excessive air supply.
Insufficient air supply.
REMEDY
Consult your Customer Service
With unit running and trigger 
gun closed, look through burner 
sight glass to ensure there is 
sparking across electrodes.
Consult your Customer Service.
Pressure should be over 250 
PSI/18 Bar to allow burner to 
come on.
Unit will automatically reignite 
when cool.
Adjust as explained on page 26.
Replace.
Drain fuel filter/water separator. 
Drain fuel tank, and replace with 
clean fuel.
Replace element.
Replace.
Consult Customer Service. 
Adjust as explained on page 26.
Replace.
Check fuel to ensure it is 
correct. Drain tank and replace 
filter if necessary and refill with 
proper fuel.
Check fuel pump pressure, 
adjust or replace if needed.
Replace.
Adjust as explained on page 26.
Consult your Customer Service.
Refuel. If white smoke persists, 
consult Customer Service.
Adjust as explained on page 26.
Adjust as explained on page 26.
29

Advertisement

Table of Contents
loading

Related Products for Xtream HW2765HAD

Table of Contents