PRE-START INSPECTION PROCEDURES

Before starting the unit, perform the following procedures:
1. Check the oil level in the pump and engine.
2. Inspect the water inlet strainer. Clean or replace if necessary. See 
"Water Supply", #2, pg 16.
3. Check all hose connections to ensure they are securely tightened. See 
"Water Supply", #3, pg. 16.
4. Inspect for system water leaks, oil leaks and fuel leaks. If a fuel leak is 
found, DO NOT START UNIT! See "Risk of Explosion or Fire", pg. 7. 
Be sure that all damaged parts are replaced and that the mechanical 
problems are corrected prior to operation of the unit. If you require 
service, contact Customer Service.
5. Inspect high pressure hoses for kinking, cuts and leaks. If a cut or leak 
is found, DO NOT USE HOSE! Replace hose before starting unit. See 
"Risk of Injection" pg. 8. Be sure that all damaged parts are replaced 
and that the mechanical problems are corrected prior to operation of 
the unit. If you require service, contact Customer Service.