r Error response
String
"ERR1"
"ERR2"
"ERR3"
Message
"ERR4"
"ERR5"
"ERRA"
Data length
4 bytes
When web control administrator rights password is not set (Non-protect mode)
Connecting
1)
Obtain the IP address and port number (Initial set value = 1024) of the projector and request for a
connection to the projector.
f You can obtain both the IP address and the port number from the menu screen of the projector.
IP address
Port number
2)
Check the response from the projector.
Command
example
Data length
f Mode: 0 = Non-protect mode
Command transmission method
Transmit using the following command formats.
r Transmitted data
Command
example
0x30
Data length
1 byte
r Received data
Command
example
0x30
Data length
1 byte
168 - ENGLISH
Chapter 6 Appendix — Technical information
Undefined control command
Out of parameter range
Busy state or no-acceptable period
Timeout or no-acceptable period
Wrong data length
Password mismatch
Obtain from the [NETWORK] menu → [NETWORK STATUS]
Obtain from the [NETWORK] menu → [NETWORK CONTROL] → [COMMAND PORT]
Data section
"NTCONTROL"
(ASCII string)
9 bytes
Header
'0'
Header
'0'
Details
Blank
' '
0x20
1 byte
'0'
Control command
0x30
1 byte
'0'
Control command
0x30
1 byte
Mode
'0'
0x30
1 byte
Data section
(ASCII string)
Undefined length
Data section
(ASCII string)
Undefined length
Termination
symbol
(CR)
0x0d
1 byte
Termination
symbol
(CR)
0x0d
1 byte
Termination
symbol
(CR)
0x0d
1 byte
Termination
symbol
(CR)
0x0d
1 byte