Technical Data

MAX
OUTPUT
BURNER
TYPE
Kw
Small
Auxiliary
1.00
burner
Medium
Semi-rapid
1.75
Burner
Large
rapid
3.0
burner
Triple
flame
3.80
burner
Gas intake connection
Electricity supply
supply
Battery

Instructions for the installation technician

CAUTION: This appliance must only be installed and used in rooms with
permanent ventilation to local standards.
Installation of the appliance and its connection to the electrical mains must
only be carried out by QUALIFIED STAFF.
Before any procedure, it is important to check that the appliance is
DISCONNECTED from the electrical mains. The Manufacturer declines all
responsibility for any damage deriving from installation in breach of the
regulations in force or from failure to comply with the accident prevention
regulations.
MIN
OUTPUT
20mbar
Nozzle
Kw
Making
mm
0.30
0.70
0.65
0.97
1.0
1.15
1.30
1.35
G1/2"
AC 220-240v 50/60Hz
DC 1.5v
G20
G30/31
20-30/37mbar
Nozzle
Cons
Making
3
M
/h
mm
0.095
0.50
0.157
0.65
0.286
0.85
0.35
0.97
G30
50mbar
Nozzle
Cons
Cons
Making
g/h
M
mm
73
0.43
120
0.58
219
0.75
280
0.77
3
/h
73
120
219
280
9