Boiler Safety Devices - Glow-worm Ultrapower 100sxi Instructions For Use Manual

Hide thumbs Also See for Ultrapower 100sxi:
Table of Contents

Advertisement

Boiler Shutdown
The boiler software is designed to recognise the potential for
an overheat lockout and will shutdown before this happens.
To restart the boiler, press the reset button, see diagram 2.
If the boiler fails to resume normal operation and all external
controls are calling for heat, then call your Installation/Servicing
company or Glow-worm service.
Frost Protection
With the gas and electric supplies ON and irrespective of any
room thermostat setting, the integral frost protection device
will operate the pump when the temperature of the boiler
O
water falls below 8
C.
The pump will stop after 10 minutes if the temperature is
higher than 10
O
C or has already reached 35
The burner will only activate if the boiler temperature does not
reach 10
O
C after 30 minutes or at any time if the temperature
drops to 5
O
C.
The burner will switch off when the temperature reaches
O
35
C.
NOTE: Any other exposed areas of the system should be
protected by a separate frost thermostat.
Cylinder Protection
The cylinder also has integral frost protection and should the
temperature fall below 10°C the cylinder water will be heated
to 15°C.
Supplied By www.heating spares.co Tel. 0161 620 6677

Boiler Safety Devices

Condensate Drain Blockage
As a safety feature the boiler will stop working if the condensate
drain becomes blocked. During freezing conditions this may
be due to the forming of ice in the condense drain external to
the house. Release an ice blockage by the use of warm cloths
on the pipe. The boiler should then restart. Contact your
Installation/Servicing company or Glow-worm service if the
fault persists.
Disinfection Cycle
The cylinder has a built in disinfection cycle which raises the
water temperature to 70
2.00am.
Safety Discharge Valves
O
C.
Safety discharge valves and discharge pipes are fitted to the
boiler. These valves MUST NOT be touched. If there is any
discharge from the pipes, switch off the boiler electrical
supply, then call your Installation/Servicing company or
Glow-worm service.