  • Page 1 RoughDeck Low-Profile Floor Scale SS, HE, HP*, HP-H*, HC*, AND ALTRALITE* Installation Manual * utilizes economical junction box 16960...
  • Page 2: Table Of Contents

    *NOTE: In addition to the SS and HE model RoughDecks with stainless steel j-box, this manual pertains to RoughDeck models HP, HP-H, HC, and ALTRALITE, which utilize a plastic junction box. Copyright © 2000 Rice Lake Weighing Systems. All rights reserved. Printed in the United States of America. Specifications subject to change without notice.
  • Page 3: Introduction

    1.0 Introduction Model Designations The model identification label is located on the side of the frame next to the slide-out junction box. Include both model number and serial number when ordering replacement parts. General Description NOTE: The RoughDeck™ Floor Scales are fully electronic, low A duplicate label is afixed inside the J-Box opening.
  • Page 4: Installation

    2.0 Installation If lifting the scale using a spreader bar, use only a properly designed spreader Caution bar as shown in Figure 1. Lifting force must be vertical to avoid bending the eye Overview bolts. Standard installation of the RoughDeck floor scale consists of the following steps: 1.
  • Page 5: Mounting Plate Installation

    2.4.2 Mounting Plate Installation For permanent applications, the scale should be secured to the floor to prevent sideways movement. Two mounting plates, with holes that slightly exceed the foot diameter, are – available as an option for that purpose. Lift the scale so that the feet are approximately one inch off –...
  • Page 6: Pit Installation

    When the interface cable is protected and in its final position, complete connections to the indicator. See indicator installation manual for wiring information. If necessary, trim corners as described in Section 3.2. Check all strain relief fittings for tightness. Slide the junction box tray into the cutout and secure it with the two #10 x "...
  • Page 7: Access Ramps

    Access Ramps Corner Correction Access ramps for RoughDeck floor scales are designed to All assembled RoughDeck scales are delivered with the bolt to the floor, with built-in mounting plates that attach to junction box corner-trimmed. Corner trimming is only the scale feet. When used with access ramps, side movement necessary after replacing a load cell.
  • Page 8: Calibration Procedure

    4.0 Service Information Load Cell Replacement Replacement load cells can be ordered from Rice Lake Weighing Systems according to the part numbers in the chart on page 9. Troubleshooting Guide Lift scale with chains and proper spreader bar and remove System does not operate—no display...
  • Page 9: Load Cell Wiring To Junction Box

    Note that in Figure 11 both the scale and the junction box are Do not cut load cell cables. Coil extra cable before it enters viewed from the bottom. To verify correct load cell/junction the junction box, tie with cable ties, and insert the coils into box terminal matching, see the numbers on the terminals the channel.
  • Page 10: Replacement Parts List And Accessories

    Replacement Parts List and Accessories The following tables list the pit frames, access ramps, and replacement load cell part numbers for HP, HC, HE, SS, and HP-H model RoughDeck floor scales. 4.4.1 Pit Frames Table 3 shows the pit frames available for RoughDeck scales. o f t e z i r o f...
  • Page 11: Load Cells

    Table 5 shows the standard access ramps available for 20K and 30K lb-capacity RoughDeck scales (HP-H models). r o f " 4 " 4 " 4 " 4 " 4 " 5 " 5 " 5 " 5 " 5 4.4.3 Load Cells Table 6 lists the replacement load cells for all RoughDeck models.
  • Page 12 Replacement Parts List and Accessories Standard Plastic Junction Box Stainless Steel Junction Box Description Part Number Junction Box, Standard Plastic -- 4 Channel, Signal Trim (HP/HP-H/HC models) ... 21172 Junction Box, NEMA 4X -- 4 Channel, Signal Trim (SS and HE models) ....21173 Strain Relief Flex Fitting (HP/HP-H/HC models) ............
  • Page 13: Roughdeck Limited Warranty

    RoughDeck Limited Warranty Rice Lake Weighing Systems (RLWS) warrants that all RLWS equipment and systems properly installed by a Distributor or Original Equipment Manufacturer (OEM) will operate per written specifications as confirmed by the Distributor/OEM and accepted by RLWS. RoughDeck fabricated platforms and weldments are warranted against defects in materials and workmanship for five (5) years.