Control Panel LEDs

The two control panels are located on the front of the SC118GQ chassis. Each
control panel has six LEDs. These LEDs provide critical information related to dif-
ferent parts of the system. This section explains what each LED indicates when
illuminated and any action that may be required..

Overheat/Fan Fail/UID LED

When this LED fl ashes it indicates a fan failure. When continuously on (not fl ash-
ing) it indicates an overheat condition, which may be caused by cables obstructing
the airfl ow in the system or the ambient room temperature being too warm. Check
the routing of the cables and make sure that all fans are present and operating
normally. Also check to make sure that the air shrouds are installed and that the
top cover is on. Finally, verify that the heatsinks are installed properly. This LED
will remain fl ashing or on as long as the overheat condition exists. When used with
a UID-compatible motherboard, the UID function is used to turn on or off the blue
light function of the the LED. Once the blue light is activated through the system
software, the unit can be easily located in very large racks and server banks.
2

NIC2

Indicates network activity on GLAN2 when fl ashing .
1

NIC1

Indicates network activity on GLAN1 when fl ashing .