Motor cut-out compressor (MB1)
Possible cause 1: Intermittent fault or overload on the power
supply.
Possible cause 2: Current level (A) on the motor cut-out is set
too low.
Possible cause 3: Contactor or cut-out faulty, or loose electrical
connections to the compressor.
Possible cause 4: Compressor error.
Motor cut-out HTF pump (MB2)
Possible cause 1: The HTF pump is blocked due to
contamination.
Possible cause 2: Faulty electric motor on HTF pump.
Possible cause 3: Temporary error.
Alarm
(MB1)
Compr. circ. switch
040622 16:08:15
Info
Ackn.
Note
Alarm
(MB2)
HTF c-pump switch
040622 16:08:15
Info
Ackn.
Note

Menu outline for Basic functions (Customer level 1)

Reg 637
K1
040622 16:08:15 Tu
Heat
Info
Menu
Main menu
Indoor temperature
settings
Heat. +/-
STANDBY
no rad heat required
No need
Temperature settings
for hot water mode
Heat. incr. / decr.
range
Heat. Fine-tune
HOT WATER MODE
Heat pump only
Heat. settings
Adjust Heat.
range
Room temperature
HEATING MODE
HP and add. heat
Heat. settings
Int. Heat
Extra hot water
Heat rad required
Heat pump starts
in #### seconds

Select scrolling information on the menu display

Note
Main menu
Main menu
Adjusting the hot
Monitor all
1
water settings
2
temperatures
Hot water setting
Temperature readings
Duration of
Return radiator
0-10
1.1
add. hot water
2.1
Temperature readings
Out GT2
-0/+10
1.2
Temperature readings
Hot water GT3
Temperature readings
Shunt. flow GT4
1.10
Temperature readings
Room GT5
Temperature readings
Compressor GT6
Temperature readings
Heat tr fluid out GT8
Temperature readings
Heat tr fluid in GT9
Temperature readings
Ht trfld(coll) in GT10
Temperature readings
Httrfld(coll) out GT11
Reg 637
K1
040622 16:08:15 Tu
Heat
Info
Menu
3
GT1