Sanyo Big PACi 18 Series Technical Data & Service Manual page 153

Big pack i dc inverter
Table of Contents

Advertisement

2-8-3. Setting the outdoor unit system addresses
For basic wiring diagram 2 (Set the system addresses:
1, 2, 3...)
Outdoor unit control PCB
System address rotary switch
(Set to "0" at time of shipment)
System address rotary switch
2
System address
10s
20s
DIP switch
ON
ON
1
2
OFF
8 – 10 HP
OC (CN500, BLU)
63PH (CN027, WHT)
FUSE (0.5A, F500)
EXCT
(CN030, RED)
RC P
(CN039, RED)
IC002
FUSE
(6.3A, F101)
CTL2
(CN202, GRN)
CTL1
(CN203, GRN)
N . P . C H E C K
(CN046, RED)
R.C.ADD. Rotary switch
MODE (CN038)
System address
No.
0 Automatic address
(Setting at shipment = "0")
1 (If outdoor unit is No. 1)
2 (If outdoor unit is No. 2)
11 (If outdoor unit is No. 11)
21 (If outdoor unit is No. 21)
30 (If outdoor unit is No. 30)
8 – 10 HP
EMG (CN502, BRN)
SILENT (CN037, WHT)
PUMP DOWN (CN048)
TEMINAL (CN205, BLK)
C2 (CN020, WHT)
C1 (CN021, WHT)
TS (CN022, RED)
TO (CN023, BLK)
TD (CN024, BLK)
MOV1
(CN300, WHT)
MOV2
(CN301, BLK)
LED (D041)
EEPROM
LED2
TEST (CN033, RED)
LED1
C-CHK (CN035)
A.ADD (CN047)
R.C.ADD. DIP switch
IC001
D115
Fig. 2-7
System address
System address
10s digit
1s place
(2P DIP switch)
(Rotary switch)
Both OFF
"0" setting
ON
ON
1
2
OFF
Both OFF
"1" setting
ON
ON
1
2
OFF
Both OFF
"2" setting
ON
ON
1
2
OFF
10s digit ON
"1" setting
ON
ON
1
2
OFF
20s digit ON
"1" setting
ON
ON
1
2
OFF
10s digit and 20s
digit ON
"0" setting
ON
ON
1
2
OFF
2-8-4. Automatic address setting using the remote
controller
When the outdoor unit shown in "2-8-2. Basic wiring
diagram 2" is used for group control of multiple units,
use the remote controller to perform automatic address
setting. (During automatic address setting, "SETTING"
blinks on the remote controller display.)
Press the remote controller timer time
button simultaneously. (Hold for 4 seconds or
longer.) Then press the
appears: All systems automatic address setting.)
(Automatic address setting is performed in sequence
for all outdoor units from No. 1 to No. 30. When auto-
matic address setting is completed, the units return to
normal stopped status.)
To select each refrigerant system individually and per-
form automatic address setting, press the remote
controller timer time
neously. (Hold for 4 seconds or longer.) Then press
either of the temperature setting
(Item code "A1" appears: Individual system automatic
address setting)
Use either the
outdoor unit to perform automatic address setting for.
(R.C.1 is displayed.) Then press the
(Automatic address setting is performed for refrigerant
system 1.) When automatic address setting for system
1 is completed, the system returns to normal stopped
status.
Again press the remote controller timer time
and the
button simultaneously.
Then in the same way as above (use the
to display "R.C.2"), select the next system and perform
automatic address setting.
2-8-5. Indicating (marking) the indoor and outdoor
unit combination number
Indicate (mark) the number after automatic address
setting is completed.
(1) So that the combination of each indoor unit can be
easily checked when multiple units are installed,
ensure that the indoor and outdoor unit numbers
correspond to the system address number on the
outdoor unit control PCB, and use a magic marker
or similar means which cannot be easily erased to
indicate the numbers in an easily visible location on
the indoor units (near the indoor unit nameplates).
Example: (Outdoor) 1 - (Indoor) 1, 2...
(Outdoor) 2 - (Indoor) 1, 2...
(2) These numbers will be needed for maintenance.
Be sure to indicate them.
* Use the remote controller to check the addresses
of the indoor units. Press and hold the
and
button for 4 seconds or longer (simple set-
tings mode).
Then press the
address. (Each time the button is pressed, the add-
ress changes as follows: 1-1, 1-2, ... 2-1, 2-2, ....)
The indoor unit fan operates only at the selected
indoor unit. Confirm that correct fan is operating,
and indicate the address on the indoor unit.
Press the
button again to return to the normal
remote controller mode.
For details, refer to the separate manual.
2-8
button and
button. (Item code "AA"
button and
button simulta-
/
buttons.
or
button to select the
button.
button
button and select the indoor
button
button

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents