Removing The 20A Line Fuseholder, Power Supply Cord, And Line Filter Capacitor - KitchenAid KBMS1454R Technical Education

Kitchenaid built-in microwave oven technical education
Hide thumbs Also See for KBMS1454R:
Table of Contents

Advertisement

REMOVING THE 20A LINE FUSEHOLDER, POWER
SUPPLY CORD, AND LINE FILTER CAPACITOR
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug microwave oven or disconnect
power.
2.
Remove the microwave oven from its
mounting location.
3.
Remove the top cover from the microwave
(see steps 3 and 4 on page 4-2 for the
procedure).
4.
CAUTION: Discharge the line filter and
high voltage capacitors using a
20,000 Ω resistor from the terminals to
chassis ground.
Power Supply Cord
Line Filter Capacitor
20A Line Fuse
5.
6.
HV Capacitor
4-10
To remove the 20A line fuseholder:
a) Remove the fuse from the fuseholder.
b) Disconnect the two wire connectors
from the terminals.
c) Remove the T10 Torx screw from the
fuseholder and remove the fuseholder.
Brn Wires
To remove the power supply cord:
a) Disconnect the white and black power
supply cord wires from the line filter
capacitor terminals.
b) Disconnect the green ground wire from
the ground terminal.
Power Supply Cord
White Wire
Black Wire
Fuseholder
Screw
Green Ground Wire

Hide quick links: