Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
COOLING FAN MOTOR
Refer to page 4-12 for the procedure for ac-
cessing the cooling fan motor.
1.
Unplug microwave oven or disconnect
power.
2.
Disconnect the wire connectors from the
cooling fan motor terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the
motor terminals. The meter should indicate
approximately 10 Ω.
WARNING
Electrical Shock Hazard
MAGNETRON THERMOSTAT (N.C.)
Refer to page 4-15 for the procedure for ac-
cessing the magnetron thermostat.
1.
Unplug microwave oven or disconnect
power.
2.
Disconnect the wires from the magnetron
thermostat terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the
terminals. The meter will indicate a closed
circuit (0 Ω) at room temperature. NOTE:
The thermostat opens @ 293°F / 145°C
and resets (closes) @ 250°F / 121°C.
5-5