REMOVING THE DISPLAY, TOUCH PANEL BOARD,
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug microwave oven or disconnect
power.
2.
Remove the microwave oven from its
mounting location.
3.
Remove the user interface board from its
holder (see page 4-2 for the procedure).
4.
Remove the two T20 Torx screws from the
user interface board holder and remove
the holder from the subpanel.
User Interface Board
Holder Screws
& SELECTOR BOARD
5.
6.
7.
4-3
Remove the four T20 Torx screws (two on
each side) from the control panel assem-
bly and remove the assembly from the
unit.
Control Panel
Screws
Place the control panel on a padded work
surface.
Control Panel
To remove the display, press out on the
four holder clips, and pull the display out of
the holder.
Clips
Display