GENERATOR AC VOLTAGE CONNECTIONS
DESCRIPTION
The regulator is equipped with seven numbered terminals (0
to 6) and their related brass jumpers. The illustrations show
connection points and jumpers for the 3 phase configuration
of the generator. The sensing leads connect between pin # I
and pin #2 on the AC tenninal block and connection #2 and
#0 on the voltage regulator board.
NOTE:
Series Delta requires the installation of a jumper on
the regulator board between tem.inal Band
10.
170-270 V
1BO-160V
+
BlK AVR
CASE GND
BlK AVR
CASE GND
-N/GND
UI
VI
L1
l2
l3
GRN AVR
UI
VI
WI
L1
l2
l3
GRN GND
BE THREE PHASE (SIX WIRE)
o
3 PHASE VOLTAGE REGULATOR
PARALLEL WYE (STAR)
L·N -120 VAC 10 60 Hz
L·N -110 VAC 10 60 Hz
SERIES WYE (STAR)
L·L - 450 VAC 30 60 Hz
L·N - 265 VAC 10 60 Hz
L3
N
BE THREE PHASE (TWELVE WIRE)
...v-
WESTERBEKE
Engines & Generators
30
SERIES DELTA
L·L - 240 VAC 30 60 Hz
L2, L3-N - 120 VAC 10 60 Hz
A. SERIES DELTA - Note the
repositioning of the ground
lead from neutral to gener·
ator housing.
J. Jumper using #10 AWG
Wire .