Level 1 Programming; Level 2 Programming - Bunn H5E-DV PC Installation & Operating Manual

Table of Contents

Advertisement

When power is applied to the dispenser, the display located on the bottom of the main circuit board will show
the revision level of the software for 5 seconds, and then go to (-). While the tank is fi lling, the display will read
(FIL). When the tank is full the display will return to (-).

LEVEL 1 PROGRAMMING

TANK WATER TEMPERATURE & READY TEMPERATURE SET-UP
1. Press and hold the center button until P1 appears on the display (approximately 3
seconds) then release button. The tank water temperature set point will appear on
the display (Factory default is 90° F).
2. Use the (+) button to increase the temperature set point, and the (-) button to de-
crease the set point.
3. Press and release the center button once more. The display will read P2, then show
the ready temperature set point (Factory default is 85°F).
4. Use the (+) button to increase the temperature set point, and the (-) button to de-
crease the set point.
5. To exit Level 1 Program press and release the center button once more. The display
will read (-).

LEVEL 2 PROGRAMMING

DISPENSE TEMPERATURE LOCKOUT, FAHRENHEIT OR CENTIGRADE SELECTION, &
FACTORY DEFAULTS
1. Press and hold the center button until H1 appears on the display (approximately 6
seconds) then release button. The display will either read noL (LOCKOUT DISABLED)
or Loc (LOCKOUT ENABLED).
2. Use the (+) and (-) buttons to alternate between Loc and noL.
PROGRAMMING
8
P3747
39338 100606

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents