HOW TO SET UP YOUR UNIT

Location of the Air Compressor
Locate the air compressor in a clean, dry and well
ventilated area. The air compressor should be locat-
ed at least 12" away from the wall or other obstruc-
tions that will interfere with the flow of air. The air
compressor pump and shroud are designed to allow
for proper cooling. The ventilation openings on the
compressor are necessary to maintain proper oper-
ating temperature. Do not place rags or other con-
tainers on or near these openings.The air filter must
be kept clear of obstructions which could reduce air
flow to the air compressor.

GROUNDING INSTRUCTIONS

a short circuit, grounding reduces the risk of
shock by providing an escape wire for the
electric current. This air compressor must be
properly grounded.
The portable air compressor is equipped with a cord
having a grounding wire with an appropriate ground-
ing plug (see following illustrations). The plug must
be used with an outlet that has been installed and
grounded in accordance with all local codes and
ordinances.
1. The cord set and plug with this unit contains a
grounding pin. This plug MUST be used with a
grounded outlet.
IMPORTANT: The outlet being used must be
installed and grounded in accordance with all local
codes and ordinances.
2. Make sure the outlet being used has the same
configuration as the grounded plug. DO NOT
USE AN ADAPTER. See illustration.
Plug
Grounding Pin
3. Inspect the plug and cord before each use. Do
not use if there are signs of damage.
4. If these grounding instructions are not com-
pletely understood, or if in doubt as to whether
the compressor is properly grounded, have the
installation checked by a qualified electrician.

INSTALLATION

RISK OF ELECTRICAL
SHOCK. In the event of
Grounded
Outlets
TRICAL SHOCK.
Do not modify the plug provided. If it does
not fit the available outlet, a correct outlet
should be installed by a qualified electrician.
Repairs to the cord set or plug MUST be
made by a qualified electrician.

Extension Cords

Use extra air hose instead of an extension cord to
avoid voltage drop and power loss to the motor, and
to prevent overheating.
If an extension cord must be used, be sure it is:
a 3-wire extension cord that has a 3-blade
grounding plug, and a 3-slot receptacle that will
accept the plug on the product
in good condition
no longer than 50 feet
12 gauge (AWG) or larger. (Wire size increases
as gauge number decreases. 10 AWG and 8
AWG may also be used. DO NOT USE 14 OR 16
AWG.)

Voltage and Circuit Protection

Refer to the Parts Manual for the voltage and mini-
mum branch circuit requirements.
Certain air compressors can be operated on a 15
amp circuit if the following conditions are met.
1. Voltage supply through branch circuit is 15
amps.
2. Circuit is not used to supply any other electrical
needs (lights, appliances, etc.).
3. Extension cords comply with specifications.
4. Circuit is equipped with a 15 amp circuit breaker
or 15 amp time delay fuse. NOTE: If compressor
is connected to a circuit protected by fuses, use
only time delay fuses. Time delay fuses should
be marked "D" in Canada and "T" in the US.
If any of the above conditions cannot be met, or if
operation of the compressor repeatedly causes
interruption of the power, it may be necessary to
operate it from a 20 amp circuit. It is not necessary
to change the cord set.
9 - ENG
IMPROPER GROUNDING
CAN RESULT IN ELEC-
D23012