Craftsman 919.165180 Owner's Manual

Permanently lubricated single stage horizontal portable air compressor
Hide thumbs Also See for 919.165180:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Owner's Manual
Permanently Lubricated
Single Stage
Horizontal Portable

AIR COMPRESSOR

Model No.
919.165180
• Safety Guidelines
• Assembly
• Operation
• Maintenance
• Service and Adjustments
• Troubleshooting
• Repair Parts
• Español
CAUTION:
Read the Safety Guidelines
and All Instructions Carefully Before
Operating.
Sears, Roebuck and Co., Hoffman Estates, IL 60170 U.S.A.
Visit our Craftsman website: www.sears.com/craftsman
D24580
Rev. 1
11/7/01

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Craftsman 919.165180

  • Page 1: Air Compressor

    • Service and Adjustments • Troubleshooting • Repair Parts • Español CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60170 U.S.A. Visit our Craftsman website: www.sears.com/craftsman D24580 Rev. 1 11/7/01...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS WARRANTY ..........2 SPECIFICATION CHART .
  • Page 3: Safety Guidelines

    SPECIFICATION TABLE Model No. 919-165180 Max. Developed HP Bore 2.38" Stroke 1.35" Voltage-Single Phase Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity 25 gallons Approximate Cut-in Pressure Approximate Cut-out Pressure SCFM @ 40 psig SCFM @ 90 psig Refer to Glossary for abbreviations SAFETY GUIDELINES - DEFINITIONS This manual contains information that is important for you to know and understand.
  • Page 4 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT. HAZARD WARNING: RISK OF EXPLOSION OR FIRE WHAT CAN HAPPEN HOW TO PREVENT IT ALWAYS OPERATE THE COMPRESSOR IN A...
  • Page 5 HAZARD WARNING: RISK OF BURSTING AIR TANK: THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK, AND RESULT IN A VIOLENT TANK EXPLOSION AND COULD CAUSE PROPERTY DAMAGE OR SERIOUS INJURY. WHAT CAN HAPPEN HOW TO PREVENT IT FAILURE TO PROPERLY DRAIN DRAIN TANK DAILY OR AFTER EACH USE.
  • Page 6 HAZARD WARNING: RISK OF ELECTRICAL SHOCK WHAT CAN HAPPEN HOW TO PREVENT IT NEVER OPERATE THE COMPRESSOR YOUR AIR COMPRESSOR IS POWERED BY OUTDOORS WHEN IT IS RAINING OR IN WET ELECTRICITY. LIKE ANY OTHER CONDITIONS. ELECTRICALLY POWERED DEVICE, IF IT IS NOT USED PROPERLY IT MAY CAUSE NEVER OPERATE COMPRESSOR WITH ELECTRIC SHOCK.
  • Page 7 HAZARD WARNING: RISK OF BURNS WHAT CAN HAPPEN HOW TO PREVENT IT TOUCHING EXPOSED METAL SUCH AS THE NEVER TOUCH ANY EXPOSED METAL COMPRESSOR HEAD OR OUTLET TUBES, PARTS ON COMPRESSOR DURING OR CAN RESULT IN SERIOUS BURNS. IMMEDIATELY AFTER OPERATION. COMPRESSOR WILL REMAIN HOT FOR SEVERAL MINUTES AFTER OPERATION.
  • Page 8 HAZARD WARNING: RISK OF PROPERTY DAMAGE WHEN TRANSPORTING COMPRESSOR (Fire, Inhalation, Damage to Vehicle Surfaces) WHAT CAN HAPPEN HOW TO PREVENT IT OIL CAN LEAK OR SPILL AND COULD ALWAYS PLACE COMPRESSOR ON A RESULT IN FIRE OR BREATHING HAZARD, PROTECTIVE MAT WHEN TRANSPORTING TO SERIOUS INJURY OR DEATH CAN RESULT.
  • Page 9: Glossary

    GLOSSARY When the tank pressure drops to a Become familiar with these terms certain low level the motor will restart before operating the unit. automatically. The low pressure at CFM: Cubic feet per minute. which the motor automatically SCFM: Standard cubic feet per restarts is called “cut-in”...
  • Page 10: Assembly

    ASSEMBLY Contents of Carton Assemble Wheels 1 - Air Compressor It will be necessary to brace or support 1 - Handle one side of the air compressor 4 - Self Tapping Screw when installing the wheels because the air compressor will have a 2 - Wheels tendency to tip.
  • Page 11: Installation

    INSTALLATION HOW TO SET UP YOUR Make sure the outlet being used has the same configuration as UNIT the grounded plug. DO NOT Location of the Air Compressor USE AN ADAPTER. See Locate the air compressor in a clean, illustration. dry and well ventilated area.
  • Page 12 Extension Cords Voltage and Circuit Protection Using extension cords is not Refer to the specification table for the recommended. The use of extension voltage and minimum branch circuit cords will cause voltage to drop requirements. resulting in power loss to the motor Certain air compressors can be and overheating.
  • Page 13: Operation

    OPERATION Know Your Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Outlet Pressure Gauge: The outlet Description of Operation pressure gauge indicates the air Become familiar with these controls...
  • Page 14: How To Use Your Unit

    Check Valve: When the air If the overload protector shuts the compressor is motor off frequently, check for a operating, the possible voltage problem. Low Check Valve check valve is voltage can also be suspected when: “open”, allowing The motor does not get up to full compressed air power or speed.
  • Page 15: How To Start

    Move the On/Auto/Off lever to How to Start: "ON/AUTO" position. The Turn the On/Auto/Off lever to compressor will start. “AUTO” and allow tank pressure Run the compressor for 15 to build. Motor will stop when minutes. Make sure the drain tank pressure reaches “cut-out”...
  • Page 16: Maintenance

    MAINTENANCE Customer Responsibilities Daily or Before Every Every after each Yearly each hours hours Check Safety Valve Drain Tank Air Filter Air compressor pump intake and exhaust valves 1- more frequent in dusty or humid conditions Unit cycles To Check Safety Valve automatically when If the safety valve power is on.
  • Page 17 After the water has been drained, Remove the air filter retainer. close the drain valve (clockwise). Remove the air filter and make The air compressor can now be sure it is clean. stored. IMPORTANT: Do not operate the NOTE: If drain valve is plugged, compressor with the air filter release all air pressure.
  • Page 18: Service And Adjustments

    SERVICE AND ADJUSTMENTS Unit cycles Unscrew the check valve (turn automatically when counterclockwise) using a 7/8” power is on. When doing open end wrench. Note the Maintenance, you may be exposed orientation for reassembly. to voltage sources, compressed air Using a screwdriver, carefully or moving parts.
  • Page 19 Apply pipe sealant tape to the To Replace Regulator nipple. Release all air pressure from air Assemble the regulator and tank. See “To Drain Tank” in the orient as shown. Maintenance section. NOTE: Arrow indicates flow of air. Unplug air compressor. Make sure it is pointing in the Remove the regulator ring and direction of air flow.
  • Page 20: Storage

    STORAGE Before you store the air compressor, Water will make sure you do the following: condense in the air tank. If not drained, water will Review the "Maintenance" corrode and weaken the air tank section on the preceding pages causing a risk of air tank rupture. and perform scheduled maintenance as necessary.
  • Page 21: Troubleshooting

    TROUBLESHOOTING Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure. PROBLEM CAUSE CORRECTION...
  • Page 22 PROBLEM CAUSE CORRECTION Pressure reading It is normal for "some" If there is an excessive on the regulated pressure drop to occur. amount of pressure drop pressure gauge when the accessory is used, drops when an adjust the regulator following accessory is the instructions in the used.
  • Page 23 PROBLEM CAUSE CORRECTION Regulator will Replace Damaged regulator not shut off air outlet. Motor will not Motor overload protection Let motor cool off and run. overload switch will switch has tripped automatically reset. Tank pressure exceeds Motor will start automatically when tank pressure drops pressure switch “cut-in”...
  • Page 24 CONTENIDO GARANTÍA ............28 CUADRO DE ESPECIFICACIONES .
  • Page 25: Cuadro De Especificaciones

    CUADRO DE ESPECIFICACIONES Modelo Nº 919-165180 Máx. HP desarrollado Diámetro interior 2,38” (60,452mm) Carrera 1,35” (34,29mm) Tensión monofásica 120V/60/1 Circuito mínimo requerido Tipo de fusible Acción retardada Capacidad de aire en el tanque 25 Galones (94,6 litros) Presión de corte de entrada Presión de corte de salida SCFM a 40 psig 8,6 Calibre de libras...
  • Page 26 INSTRUCCIONES IMPORTANTES DE SEGURIDAD GUARDE ESTAS INSTRUCCIONES LA OPERACIÓN O EL MANTENIMIENTO INADECUADOS DE ESTE PRODUCTO PODRÍAN OCASIONAR SERIAS LESIONES Y DAÑOS A LA PROPIEDAD. LEA Y COMPRENDA TODAS ADVERTENCIAS INSTRUCCIONES FUNCIONAMIENTO ANTES DE UTILIZAR ESTE EQUIPO. PELIGRO ADVERTENCIA: RIESGO DE EXPLOSIÓN O INCENDIO ¿QUÉ...
  • Page 27 PELIGRO ADVERTENCIA: RIESGO DE EXPLOSIÓN AIR TANK: THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK, AND RESULT IN A VIOLENT TANK EXPLOSION AND COULD CAUSE PROPERTY DAMAGE OR SERIOUS INJURY. ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? DRENE EL TANQUE DIARIAMENTE O 1.
  • Page 28 PELIGRO ADVERTENCIA: RIESGO DE DESCARGA ELÉCTRICA ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? SU COMPRESOR DE AIRE ESTÁ ACCIONADO JAMÁS OPERE EL COMPRESOR A LA POR ELECTRICIDAD. COMO CUALQUIER INTEMPERIE CUANDO ESTÁ LLOVIENDO O EN CONDICIONES DE HUMEDAD. OTRO DISPOSITIVO ELÉCTRICO IMPULSADO ELÉCTRICAMENTE, SI NO SE LO UTILIZA NUNCA OPERE EL COMPRESOR SIN SUS ADECUADAMENTE, PODRÍA CAUSARLE...
  • Page 29 PELIGRO ADVERTENCIA: RIESGO DE QUEMADURAS ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? JAMÁS TOQUE PARTES DE METAL TOCAR EL METAL EXPUESTO TAL COMO EL EXPUESTAS EN EL COMPRESOR DURANTE CABEZAL DEL COMPRESOR O LOS TUBOS O INMEDIATAMENTE DESPUÉS DE LA DE SALIDA DEL ESCAPE, PUEDE OPERACIÓN.
  • Page 30 PELIGRO ADVERTENCIA: RIESGO DE DAÑOS A LA PROPIEDAD AL TRANSPORTAR EL COMPRESOR (Fuego, inhalación, daño a la superficie de vehículos) ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? EL ACEITE PUEDE DERRAMARSE Y ELLO DEPOSITE EL COMPRESOR SOBRE UNA PODRÍA RESULTAR EN SERIAS LESIONES O ALFOMBRILLA PROTECTORA CUANDO LO LA MUERTE DEBIDO AL RIESGO DE TRANSPORTE.
  • Page 31: Glosario

    GLOSARIO Presión mínima de corte: Cuando el Familiarícese con los siguientes términos, motor está apagado, la presión del tanque antes de operar la unidad: de aire baja a medida que usted continúa CFM: (Cubic feet per minute) Pies cúbicos usando su accesorio. Cuando la presión por minuto.
  • Page 32: Ensamblado

    ENSAMBLADO Contenido de la caja Ensamble de las ruedas 1- Compresor de aire Será necesario soportar un lado 1- Manija del equipo cuando se instalan las 4- Tornillo Autorroscante ruedas porque el compresor tenderá a voltearse. 2- Ruedas Fije las ruedas con pernos con 2- Pernos con resalto, 3/8 - 16 resalto y tuercas como se muestra.
  • Page 33: Instalación

    INSTALACIÓN Asegúrese de que el tomacorriente que CÓMO PREPARAR LA UNIDAD será utilizado tenga la misma configuración que el enchufe de conexión Ubicación del compresor de aire a tierra. Ubique al compresor de aire en una zona NO UTILICE UN ADAPTADOR. Ver limpia, seca y bien ventilada.
  • Page 34 Cables de extensión eléctrica Protección del voltaje y del circuito No se recomienda la utilización de cables Acerca del voltaje y la mínima cantidad de de extensión eléctrica. El uso de cables circuitos requeridos, refiérase al cuadro de de extensión eléctrica originará una caída especificaciones.
  • Page 35: Operación

    OPERACIÓN Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD. Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicación de los distintos controles y regulaciones. Conserve este manual para referencias futuras.
  • Page 36 Válvula reguladora: Cuando el Si el protector de sobrecarga apaga el compresor de motor con mucha frecuencia, verifique si aire se hay algún posible Válvula reguladora encuentra problema de voltaje. También se puede funcionando, la sospechar de válvula bajo voltaje cuando: reguladora esta El motor no alcanza toda su potencia "abierta",...
  • Page 37 5. Haga funcionar el compresor durante 15 Cómo poner en marcha: minutos. Asegúrese de que la válvula de Mueva la palanca On/Auto/Off a la drenaje esté abierta y que la presión de posición "AUTO" y deje que se aire acumulado en el tanque sea mínima. incremente la presión del tanque.
  • Page 38: Mantenimiento

    MANTENIMIENTO Responsabilidades del cliente Antes Diariamente Cada Cada Anualmente o luego de de cada cada uso horas horas Verifique la válvula de seguridad Drenaje del tanque Filtro de aire Válvulas de entrada y escape de la bomba del compresor de aire 1- Más frecuente en condiciones polvorientas o húmedas.
  • Page 39 Dentro del tanque se Filtro de producirá condensación de agua. Si no aire drena, el agua lo corroerá y debilitará Reten del causando un riesgo de ruptura del tanque de aire. filtro de aire Una vez drenada el agua, cierre la válvula de drenaje (girando en sentido horario).
  • Page 40: Servicio Y Ajustes

    SERVICIO Y AJUSTES La unidad cicla Utilizando una llave regulable, afloje automáticamente el tubo aliviador de presión del en cuanto la energía eléctrica es tanque de aire y el interruptor de conectada. Al efectuar el mantenimiento, presión . Retire cuidadosamente la usted quedará...
  • Page 41 Aplique cinta selladora de cañerías Para reemplazar el regulador sobre el niple del tubo vertical. Libere toda la presión del aire del Ensamble el regulador y oriéntelo de tanque. Vea "Drenaje del tanque" en acuerdo a lo mostrado. la sección "Mantenimiento". NOTA: La flecha indica el sentido del flujo Desenchufe el equipo.
  • Page 42: Almacenaje

    ALMACENAJE El agua se Antes de guardar su compresor de aire, condensa dentro asegúrese de hacer lo siguiente: del tanque de aire. Si no se drena, ella Revise la sección "Mantenimiento" corroerá debilitando la paredes del de las páginas precedentes y ejecute tanque de aire, originando un riesgo de el mantenimiento programado de ruptura de sus paredes.
  • Page 43: Guía De Diagnóstico De Problemas

    GUÍA DE DIAGNÓSTICO DE PROBLEMAS El desarrollo de reparaciones puede exponer a sitios con corriente viva, partes en movimiento o fuentes de aire comprimido que podrían ocasionar lesiones personales. Antes de intentar reparación alguna, desenchufe el compresor de aire y purgue toda la presión de aire del tanque.
  • Page 44 CAUSA CORRECCIÓN PROBLEMA Si hubiese una caída excesiva de Es normal que ocurra algún La lectura de la presión durante el uso del descenso en la presión. presión sobre un accesorio, ajuste el regulador de manómetro (si acuerdo a las instrucciones de la viene equipado sección Operación.
  • Page 45 PROBLEMA CAUSA CORRECCIÓN El motor no Deje enfriar el motor y el El interruptor de protección des interruptor de sobrecarga se funciona. obrecarga del motor se ha reajustará automáticamente. abierto. El motor arrancará automáticamente La presión del tanque excede cuando la presión del tanque caiga la presión de "corte máximo"...
  • Page 46 NOTES/NOTAS D24580 50- SP...
  • Page 47 NOTES/NOTAS D24580 51- SP...
  • Page 48 Get it fixed, at your home or ours! For repair of major brand appliances in your own home . . . no matter who made it, no matter who sold it! ® 1-800-4-MY-HOME Anytime, day or night (1-800-469-4663) (U.S.A. and Canada) www.sears.com www.sears.ca For repair of carry-in products like vacuums, lawn equipment, and...

Table of Contents