H. Operation During A Power Outage
The IntelliFire intermittent pilot ignition system comes
with a battery backup system that enables the system
to operate in a power outage. A factory-installed battery
pack is located in the control cavity of the appliance. See
Figure 3.3. Batteries should not be placed in the battery
tray while using electrical power to operate the fi replace.
Remove batteries from battery tray when power has been
restored.
NOTICE: Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
To Operate Fireplace Using Battery Power (DC):
1. Access the control cavity of the appliance. See Figure
3.3 for location. The decorative front may need to be
removed.
2. Locate the battery tray in the control cavity and insert
two D cell batteries. Battery polarity must be correct or
module damage will occur. See Figure 3.3. A complete
wiring diagram is included in the Electrical section of
the appliance Installation Manual.
3. Turn the appliance on according to the instructions
below for the appropriate type of control:
Standard Wall Switch or Factory-Installed ON/OFF
Switch:
Toggle the switch as you would under normal
circumstances.
Multifunctional Wired Wall Switch Control System:
Locate the wired wall switch control module in control
cavity.
Locate battery operation switch on the side of the
module.
Slide the switch to the BATTERY ON or ON position.
Wireless Remote:
Locate the remote control module in the control cavity.
Slide the ON/REMOTE/OFF switch to the ON position.
NOTICE: Some functionality will be lost when using battery
backup including remote control, fan, lights, or any other
auxiliary functions that require household 110-120 VAC
power.
Heat & Glo • SL-550F, SL-750F Owner's Manual • 2297-981 Rev. E • 4/15
To Return to Operation Using Electrical (AC) Power
Standard Wall Switch or Factory-Installed ON/OFF
Switch:
Toggle the switch to OFF and remove the batteries
from the battery tray. Replace decorative front on
appliance.
Multifunctional Wired Wall Switch Control System:
Slide the switch to the OFF position. Remove the
batteries from the battery tray. Replace decorative
front on appliance.
Wireless Remote:
Slide the ON/REMOTE/OFF switch to the REMOTE
position. Remove the batteries from the battery tray.
Replace decorative front on appliance.
I. Detailed Component Operating Instruc-
tions - IntelliFire
IntelliFire™ Ignition System
Intellifi re™ is an intermittent pilot ignition, which is an
electronic system. The term Intermittent is used because
the pilot burner fl ame is only present when the main
burner is operating. When the main burner is off, the pilot
is also off.
NOTICE: Batteries should not be placed in the battery
pack while using the transformer. Remove batteries before
using the transformer, and unplug the transformer before
installing the batteries. Battery polarity must be correct or
module damage will occur.
Appliance ON/OFF
A wall control, thermostat or remote control may be
used to control the ON/OFF function of the appliance.
Follow instructions included with the installed control.
Optional Fan Kit
If desired, a fan kit may be added. Contact your dealer
to order the correct fan kit. Heat management for the fan
is discussed in Section 3.G. Detailed instructions are in-
cluded with the fan kit.