Cable Installation; Thermostat Installation - Dometic Royale Penguin 610115.411 Installation & Operating Instructions Manual

Roof mount air conditioner with remote electronic thermostat
Table of Contents

Advertisement

7/8" Dia. Min.
0
0
1-----
3-1/4"
6-1/4"
Shrink Wrap
5A. CABLE INSTALLATION (OEM)
A.
The thermostat should be located on an inside wall
approximately 4-1/2 feet (54') above the floor.
B.
Check the location for heat source other than room
air. (Example: cook stove, direct sunlight,
microwave oven, or lights.)
C.
A hole at least 7/8' diameter will be needed to
route the cable through the wall.
SUGGESTION: An opening 2" wide by 1" high
will make cable connection easier.
D.
The hole should be located 3-1/4' from the right
edge of the thermostat and 1-1/2" from the top.
The thermostat base is 6-1/4' long by 3-1/4' high.
Hole
in Wall for Cable
5B. CABLE INSTALLATION
(AFTERMARKET)
The same steps must be taken as for OEM installation
but routing through the ceiling and walls may not be
practical. There are metal or plastic raceways available
at most electrical distributors. This will allow routing
along the interior surface of your ceiling and wall to the
thermostat.
6. THERMOSTAT INSTALLATION
Now that the cable is run, install the thermostat.
A.
Remove the thermostat cover by gripping top and
bottom, then pull.
B.
Connect the cable to the connector on the
T
thermostat back. The plug is polarized and latches
1-1/2"
when fully engaged.
I
C. Connect remote switch wires to screw terminals if
applicable.
The cable must be routed from the thermostat to
the roof opening.
E. Choose the shortest, most direct route.
F. Three standard cable lengths are available:
1.
15 feet - Part No. 3101632.010
2.
25 feet - Part No. 3101632.028
3.
30 feet - Part No. 3101632.036
G. The air conditioning end of the cable is covered
with a heat shrink tubing. This allows cable routing
through a 7/8' diameter hole without damage to
the plug.
NOTE:
The tubing must be carefully
removed before connection to the air conditioner.
H.
Consider where screws, nails or staples might
contact the cable.
I.
Leave 3' of cable extending through the wall for
connection to the thermostat.
J.
Enough cable must extend into the 14" x 14'
opening to allow connection to the ribbon cable
from the upper unit.
Optional ON-OFF
Connector
Remote Switch
Connection
D.
Push the wire back into hole and fill excess with
insulating material.
(NOTE:
Make sure mounting
screw will not hit cable).
E.
Mount base to wall with two screws provided,
being careful to not damage touch pad.
F.
Check alignment and tighten screws.
G.
Replace cover.
7. REMOTE SWITCH
INSTALLATION (Optional)
The thermostat has provision for connection of a remote
ON/OFF switch. The user-specified switch may be
installed anywhere up to 40 feet from the thermostat.
Two conductor thermostat wires (minimum 28 AWG)
can be used for this connection and must be routed
from the switch to the thermostat.
4