Any brand names mentioned in this manual are registered trademarks of their respective owners. Liability Siqura accepts no liability for claims from third parties arising from improper use other than that stated in this manual. Although considerable care has been taken to ensure a correct and suitably comprehensive description of all relevant components, the manual may nonetheless contain errors and inaccuracies.
Introduction Document scope This manual applies to Siqura's pressurized IP PTZ dome cameras, the Siqura HSD620PRH and HSD621PRH. It describes how to install and connect the Siqura HSD620PRH and HSD621PRH cameras. Operation and configuration of the Siqura HSD620PRH and HSD621PRH cameras is covered in the user manual.
Siqura HSD620PRH/621PRH Typographical Conventions Before you start using this guide, it is important to understand the typographical conventions used in the documentation. The following kinds of formatting in the text identify special information. Formatting convention Type of Information Numbered list Step-by-step procedures.
Failure to comply with any precaution, warning, or instruction noted in the manual is in violation of the standards of design, manufacture, and intended use of the module. Siqura assumes no liability for the customer's failure to comply with any of these safety requirements.
Siqura HSD620PRH/621PRH The equipment has been tested and found to meet the CE-regulations relating to EMC, and complies with the limits for a Class B device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against interference to radio communications in any installation.
Safety Never face the camera towards the sun. Do not aim the camera at bright objects. Whether the camera is in use or not, never aim it at the sun or other extremely bright objects, as this can damage the camera. Regulations This device complies with Part 15 of the FCC Rules.
Pressurization eliminates the effects of moisture, dirt, and pollution on valuable camera equipment. This manual covers the installation of both the Siqura HSD620PRH and HSD621PRH IP cameras. In This Chapter Product Overview ...............
General Operation Requirements A minimum of one control device is required for operation, such as a control keyboard, a DVR, or a PC. The Siqura HSD620PRH and HSD621PRH contains a built-in receiver that decodes commands originating from a control device.
Dome Setup and Cable Connection Before installing or connecting the Siqura HSD620PRH and HSD621PRH, please refer to this section and complete the preliminary preparations for setting up the dome camera and establishing switch settings. In This Chapter Preparing the Siqura HSD620PRH and HSD621PRH for Installation Switch Definition ..............
It is necessary that the dome ID and communication protocol remain in the default modes when connecting the Siqura HSD620PRH and HSD621PRH cameras to other devices. The switches used for configuring these settings are located on the bottom of the dome camera. These settings are preset to operate the camera with the IP hardware.
IP cameras. Communication Switch Configuration The Siqura HSD620PRH and HSD621PRH's communication switch is specified in the table below. The default settings are depicted in the figure. You are advised to verify the accuracy of the communication switch configuration but do not change the default settings, or some functions may not work properly.
Changing host PC IP settings to the factory-default settings of the unit At this point, connect your PC to the Siqura HSD620PRH and HSD621PRH. You can connect them directly using a crossover cable, or connect both to a switch. Page 12...
Dome Setup and Cable Connection Step 2: Accessing the unit Using a standard web browser you can now log on to the Siqura HSD620PRH and HSD621PRH's internal web server. Step 3: Changing the unit's network settings The Network web page enables you to make the unit's network addressing compatible with the network it will be hooked into.
Siqura HSD620PRH/621PRH 4.6.3 Connecting, Aligning, and Mounting the Camera Once you have configured the protocol and network switches, connect the main cable to the base of the camera and make the appropriate connections. To align mount the pressurized camera: ...
Page 19
Dome Setup and Cable Connection Attach the dome to the housing Align the dome Secure the dome Connect the cable as follows: IP connection configuration Page 15...
Page 20
Siqura HSD620PRH/621PRH Cable connection in a mini wall mount Page 16...
Pressurizing the Camera Pressurizing the Camera Before mounting, the Siqura HSD620PRH and HSD621PRH camera's pressure sensor must be calibrated and the housing pressurized. The Low Pressure alarm uses an absolute pressure sensor and must be calibrated to the local altitude.
Siqura HSD620PRH/621PRH Pressurizing To pressurize the Siqura HSD620PRH and HSD621PRH camera Set the gauge or regulator from 10 to 20psi (.7 to 1.4bar). Place the air chuck on the tank valve and begin filling until pressure relief valve opens.
Corner Mount ..............24 Pole Mount ................ 25 Dome Dimensions The Siqura HSD620PRH and HSD621PRH dome dimensions are 366 x 285 x Ø285 mm (14.4 x 11.2 x Ø11.2 in). Installation Scenarios Choose your installation scenario from the list below for complete instructions for performing that installation.
6.3.1 Ceiling Mounting with a straight tube The only ceiling mount for the Siqura HSD620PRH and HSD621PRH dome cameras is the straight tube mount. Ceiling Mount: straight tube The straight tube is available in lengths of 25 cm and 30 cm.
Connect the cables to the dome camera. Then attach the dome to the outdoor tube adaptor and fix them with the supplied screw. Wall Mount There are three types of wall mounts for the Siqura HSD620PRH and HSD621PRH dome camera. Mounting with a mini wall mount, as shown in the section Mini wall mount. ...
Wall box mounting: wall box mount + gooseneck tube + waterproof boot + indoor tube adaptor Corner Mount With the corner standard mounting plate and gooseneck tube/mini wall mount, the Siqura HSD620PRH and HSD621PRH can be mounted onto the corner or a wall. Items Needed Dome camera ...
+ indoor tube adaptor + waterproof boot Pole Mount There are two ways to mount the Siqura HSD620PRH and HSD621PRH cameras on a pole: Using a thin/wide direct mount as described in the section Pole thin/wide direct mounting.
Page 30
Items Needed Dome camera Gooseneck tube and other equipped items (optional accessory) Indoor tube adaptor for the Siqura HSD620PRH and HSD621PRH (optional accessory) Waterproof boot (supplied with the indoor tube adaptor) Pole thin direct mounting (optional accessory) ...
Items Needed Dome camera Gooseneck tube and other equipped items (optional accessory) Indoor tube adaptor for the Siqura HSD620PRH and HSD621PRH (optional accessory) Waterproof boot (supplied with the indoor tube adaptor) Pole wide box (optional accessory) ...
If anything is missing, do not install the dome. Contact your supplier for assistance. In This Chapter Mounting Accessories ............29 Siqura HSD620PRH and HSD621PRH Accessories ....33 Mounting Accessories All mounting accessories are optional. To secure the camera to the tube or wall mount, all tube mounts and the mini wall mount are supplied with the following.
Page 34
Siqura HSD620PRH/621PRH WM01A / Mini Wall Mount White; 184×104×115.2 mm (7.24×4.09×4.54 in.); 0.6 kg (1.2 lbs). (Gasket plate and cable gland for IP66 rated installations included) PM05 / Swan-neck Mount White, Iron, Height: 250/500 mm (9.8/19.7 in.), Diameter: 50 mm (2 in.) 1 kg (2.2 lbs) / 1.8 kg (4 lbs).
Page 35
Appendix A: Camera Accessories WM05 / Corner Standard Mounting Plate White, 222×204×117 mm (8.7×8×4.6 in.); 2 kg (4.4 lbs); Supplied with 8mm washer ×4, spring washer×4, M8*16 screw×4, M8 nut×4. PM04 / Pole Wide Box White/Ivory, 270×166×155 mm (10.6×6.5×6.1 in.); 3.2 kg (7.1 lbs);...
Page 36
Siqura HSD620PRH/621PRH PM01 / Pole Thin Direct Mounting White/Ivory, 232×136×60 mm (9.1×5.4×2.4 in.); Diameter: 112~140 mm (4.4~5.5 in.); 0.7 kg (1.6 lbs); Supplied with stainless steel straps×4, M8*16 screw×4, washer×4. PM02 / Pole Wide Direct Mounting White/Ivory, 270×170×60 mm (10.6×6.7×2.4 in.);...
Appendix A: Camera Accessories Siqura HSD620PRH and HSD621PRH Accessories PA02 Power Adapter (optional) Input: 100~115VAC/Output: 24VAC 72VA (US) Input: 220~230VAC/Output: 24VAC 72VA (EU/UK) When wiring, make sure the G/Y wire Note: (Ground) is inserted into the mid-pin of the...
Need help?
Do you have a question about the HSD620PRH and is the answer not in the manual?
Questions and answers