3. Install the Compression Nut and hand tighten until the cable resists slipping when gently
pushed or pulled. Lightly wrench-tighten, being careful not to overtorque the Compression
Nut.
The unit with properly installed feedthrough appears as follows:
NOTE
screwdriver, or opened paperclip.
Feedthrough Body or RJ45 plug.
NOTE
your network access device (hub/switch/PC) must not exceed 300 feet.
NOTE
(included) should be applied around the assembled fitting to further enhance
durability.
- Removal of the RJ45 plug from the radio requires a tool such as a thin
- The total combined length of the Ethernet cables between the radio and
- Once mounted in a permanent location, additional weatherproofing tape
Care must be taken not to damage the