The recharge circuit has a three phase generator with permanent magneto.
The generator is directly connected to the voltage regulator. The voltage regulator is connected directly
to the earth and battery positive passing through the 15A protection fuse. Therefore this system does
not have a connection to the key switch. The three phase generator provides a significant recharge
power and at low rpm, a good compromise is obtained between distributed power and idle stability.
Stator check
Disconnect the connector from the voltage regu-
lator and check for continuity between each yellow
wire with the other two.
Ohm value: 0.7 - 0.9 Ohm.
Also check that each yellow wire is isolated from
the ground.
If non-conforming values are found, repeat the
checks on the stator; if incorrect values continue
to occur, replace the stator or repair the wiring.
ELE SYS - 8