Gilera 633499 Workshop Manual page 156

Runner purejet
Table of Contents

Advertisement

pure jet injection
GO TO point 15
15. TPS resetting successful
Press a key
GO TO point 16
16. The manual procedure is completed. For a further confirmation, check that the indications reported
in the parameters function comply with the instructions given for automatic reset.
rpm-timing sensor circuit
TERMINALS: 19 - 20
CONDITIONS: Engine driven by the starter (500-600 RPM)
STANDARD VALUES: V = 3.5 - 4
TERMINALS: 19 - 20
CONDITIONS: Idle engine
STANDARD VALUES: V = 11 - 12
COMPONENTS LAYOUT
1 Injection ECU
2 Pick - up
3 + to panel
4 + fixed
This integrated ignition and injection system requires a prompt perception of the running speed and of
the crankshaft angular position. The ECU must control the following upon each engine cycle:
INJ PJ - 34