Vanguard BHDV34N(A) Owner's Operation And Installation Manual page 10

Direct-vent fireplace
Hide thumbs Also See for BHDV34N(A):
Table of Contents

Advertisement

DIRECT-VENT FIREPLACE (NATURAL/PROPANE)
VENTING
INSTALLATION
Continued
Horizontal Termination
Configurations
Figures 16 through 20 show different con-
figurations for venting with horizontal ter-
mination. Each figure includes a chart with
vertical minimum/maximum and horizon-
tal maximum dimensions which must be
met. All connections must be sealed with
high temperature silicone sealant as speci-
fied in the second warning statement on
page 7. All horizontal terminations require
1/4" rise per 12" of horizontal run.
BGFVK Vent Kit Shown
(recommended for use
with cabinet mantels)
Horizontal Venting
Vertical (V)
Horizontal (H)
37" min.
10" max.
Figure 16 - Horizontal Termination
Configuration for Rigid Venting
®
Horizontal Venting
Vertical (V)
Horizontal (H)
44" min.
29" max.
(30° and 90° only, no vertical pipe)
55" min.
41" max.
(30° elbow, 1' vertical pipe, 90° elbow)
67" min.
60" max.
79" min.
84" max.
96" min.
20' max.
Note: This configuration for use with
corner installation.
Figure 17 - Horizontal Termination Configuration for Rigid Venting Using One
90 ° Elbow
Horizontal Venting
See information in
Figures 17 and 18 for
Vertical(V) and
Horizontal(H) maxi-
mums and minimums.
The same amounts
apply for flexible
venting.
Figure 18 - Horizontal Termination Using Flexible Venting
10
BVK Vent Kit Shown
BFGFVK and FGFVK
Vent Kits Shown