Note: Press 1 to disable this feature if you do not want to link up H3i
with an alarm or siren system.
To turn off alarm output: Verify your Admin password > Press #
ENABLE ILLEGAL DISMANTLE ALARM
H3i will trigger the alarm or siren system immediately if
somebody tries to dismantle it.
Operation: Verify your Admin password > Green LED
blinks > Buzzer emits long beep > Press 7 > Green LED
blinks > Buzzer emits long beep > Press 0 > Green LED
blinks > Buzzer emits long beep > Changes done success-
fully
Note: Press 1 to disable this feature if you do not want to use it.
APPLY MULTI VERIFICATION METHOD
You can increase your access control's security level by
applying multiple verification methods.
Operation: Verify your Admin password > Press 5 >
Green LED blinks > Buzzer emits long beep > Insert
number to represent the type of multi verification (as per
table shown) > Green LED blinks > Buzzer emits long
beep > Multi verification applied successfully
APPENDIX • TERMINAL DIMENSIONS AND MEASUREMENTS
Front View of Terminal Back Plate
38 mm
NUMBER
MULTI VERIFICATION
1
Password only
2
Card only
3
Fingerprint only
4
Fingerprint/Card/Password
5
Card + Password
6
Fingerprint + Password
ENABLE FAIL VERIFICATION ALARM
Enable device to trigger alarm or siren system when a
user fails to verify more than 3 continuous times.
Operation: Verify your Admin password > Press 0 >
Green LED blinks > Buzzer emits long beep > Press 2 >
Green LED blinks > Buzzer emits long beep > Press 0 >
Green LED blinks > Buzzer emits long beep > Changes
done successfully
Note: Press 1 to disable this feature if you do not want to use it.
10mm
38 mm
3mm
10 mm
84 mm
5
FINALIZING THE INSTALLATION
1. Check that all cable connections are done
correctly.
2. Attach the terminal to the corresponding back
plates and tighten the screws to secure the
terminal on the wall.
3. Switch on the power to the terminal.
4. Start using the terminal.
APPENDIX • POWER SUPPLY & DOOR LOCK SYSTEM WIRING DIAGRAMS
Diagram1 • Normally Close (NC)
+12V
DC12V 3A
Power Supply
GND
Release button
BUT
---
GND
EM Lock (NC)
+
Door sensor
SEN
Emergency Break 2
NO1
Glass (Type NC)
3
COM1
NC1
Override Switch
A
(Type NC)
C
AL- - -
AL+
BELL- - -
BELL+
Diagram 3 • Other Accessories
+12V
DC12V 3A
GND
Power Supply
BUT
GND
Door Sensor
SEN
NO1
COM1
NC1
AL- - -
Alarm device Type NO
or NC Dry contact
AL+
BELL- - -
BELL+
Door Lock Connectors
The terminal will trigger the alarm output (NO or NC)
for the following situations:
• Door forced open (a door sensor must first be
installed)
• Door open time out (a door sensor must first be
installed)
• Terminal has been illegally dismantled
DOOR LOCK ACCESSORIES
FingerTec offers various door lock accessories to
complement FingerTec door access products. For
more info, go to http://accessory.fingertec.com.
Diagram 2 • Normally Open (NO)
+12V
DC12V 3A
Power Supply
GND
BUT
Release button
---
GND
EM Lock (NO)
+
Door sensor
SEN
Emergency Break 1
NO1
Glass (Type NO)
3
COM1
NC1
Override Switch
B
(Type NO)
D
AL- --
AL+
BELL- - -
BELL+
WIRING PORT
USAGE
Dry Contact
NO
(Independent power supply for door lock)
• NO type door lock (NO-COM)
• NC type door lock (NC-COM)
Power Contact
NC
(Using power from terminal to power on door lock)
• NO type door lock (NO-GND)
• NC type door lock (NC-GND)
COM
Dry Contact
(Independent power supply for door lock)
• NO type door lock (NO-COM)
• NC type door lock (NC-COM)
Power contact
(Using power from terminal to power on door lock)
• COM1 - +12V
SEN
Door Sensor (SEN-GND)
GND
Release Button (BUT-GND)
BUT
AL+
Alarm System
NO or NC Type – Check in Advance Options
AL-
©
2013 FingerTec Worldwide Sdn. Bhd. All rights reserved • 062013