Air-cooled diesel engine generator welder set (36 pages)
Summary of Contents for ETQ TG12L31
Page 1
Owner’s Manual Model TG12L31 Customer support: 1-888-908-6200 www.easterntools.com...
Page 2
The ETQ air-cooled gasoline generators are widely used when electrical power is scarce. Our generators provide a portable mobile solution in supplying power for field operations during project construction.
Order Name Air-cooled generator set Tool Kit: Flat Head Screwdriver Spark Plug Wrench Wrench, 8×10 Owner’s manual ELECTRIC SHOCK AND SHORT SAFETY PRECAUTIONS CIRCUIT In order to ensure safety for the Be sure to notify the utility company consumer, please carefully follow when using the generator for backup instructions on being careful with the power.
Page 6
it cool for at least 2 minutes before excessive moisture, dust, dirt, or removing the gas cap. Loosen the gas corrosive vapors. cap slowly to relieve the pressure in the GROUNDING THE GENERATOR tank. Fill fuel tank outdoors and never overfill The National Electric Code requires that the tank.
Page 7
generator. Estimate how many surge (starting) watts you will need. Surge wattage is the short burst of power needed to start electric motor-driven tools or appliances such as a circular saw or refrigerator. STOPPING THE ENGINE Unplug all the electrical loads from the generator panel (Figure 1).
Page 8
Use a soft bristle brush to loosen caked on dirt of oil. Use a vacuum cleaner to pick up loose dirt and debris. Compressed air (not to exceed 25 psi) may be used to blow away dirt. SPARK PLUG ...
TROUBLESHOOTING IMPORTANT: If trouble persists please call our customer help line at (888) 908-6200 M-F 8-5 Central Time Problem Cause Solution Engine switch is Set engine switch to "on" position. set to "off". Fuel valve is Turn fuel valve to "open" position. turned to "closed".
LIMITED WARRANTY Eastern Tools & Equipment, Inc. will repair or replace, free of charge, any part or parts of the generator that are defective in material or workmanship or both. Transportation charges on parts submitted for repair or replacement under this Warranty must be borne by purchaser. This warranty is effective for the time period and subject to the conditions provided for in this policy.
Page 12
might occur between the customer and the dealer, listed below are some of the causes of engine failure that the warranty does not cover. Normal wear: Engines and generators, like all mechanical devices, need periodic parts service and replacement to perform well. Warranty will not cover repair when normal use has exhausted the life of a part of an engine.
Page 13
The U.S. Environmental Protection Agency (EPA), the California Air Resources Board (CARB) and Eastern Tools & Equipment, Inc. are pleased to explain the Federal and California Emission Control System Warranty on your small nonroad engine. In California, new small nonroad engines must be designed, built and equipped to meet the State’s stringent and anti-smog standards.
Need help?
Do you have a question about the TG12L31 and is the answer not in the manual?
Questions and answers