SW2 setting
Controlling status of compressor
operating frequency
ON
1
2 3 4 5 6
Comp.shell temperature (TH32)
3~217
ON
1
2 3 4 5 6
Display detail
109
Explanation for display
The following code will be a help to know the
operating status of unit.
•
The tens digit
Display Compressor operating frequency control
1
Primary current control
Secondary current control
2
•
The ones digit (In this digit, the total number of
activated control is displayed.)
Display Compressor operating frequency control
Preventive control for excessive temp-
1
erature rise of discharge temperature
Preventive control for excessive temp-
2
erature rise of condensing temperature
4
Frosting preventing control
Preventive control for excessive temp-
8
erature rise of heatsink
(Example)
The following controls are activated.
• Primary current control
• Preventive control for excessive tempe-
rature rise of condensing temperature
• Preventive control for excessive tempe-
rature rise of heatsink
3~217
(When the comp.shell thermistor detects 100°C or
more, hundreds digit, tens digit and ones digit are
displayed by turns.)
(Example) When 105°C;
0.5 secs.
LED
0.5secs.
2 secs.
1
05
Unit
Code
display
: