WALL SWITCH INSTALLATION
The installation of a wall switch allows you to activate the gas control
valve and turn the fireplace on and off. The wall switch is to be con-
nected to the incoming 120 volt regular household wiring that sup-
plies the electricity to the fireplace. Refer to Wiring Diagram, page 29.
OPTIONAL REMOTE CONTROL INSTALLATION (MODEL WRC)
Note: If using optional wireless hand-held remote control, wall switch
must be in ON position to be operational. The remote control then
becomes the switching mechanism for fireplace operation.
1.
Remove front refractory access panel by lifting up and angling
out of firebox opening (see Figure 12).
2.
WRC model receiver does not require a battery. Receiver can
be installed by first plugging short extension cord into fireplace
receptacle. Plug receiver unit into extension cord. Finally, plug
ignition module plug into receiver unit (see Figure 13).
3.
Activate remote handset battery by removing insulating tab
on back of handset (see Figure 13A). Battery is included pre-
installed.
4.
Once battery is activated, unit is ready to use.
5.
Replace front refractory access panel
Figure 12 - Removing Front Refractory Access Panel
(BRT2532TEN Model Shown)
Fireplace
Receptacle
Extension
Cord
Figure 13 - Installing the WRC Remote Receiver
12

FIREPLACE INSTALLATION

Remote
Control
Receiver
Ignition Module
Plug
Superiorfireplaces.US.com
Figure 13A - Installing Battery into Back of Handset
GAS LINE HOOK-UP
WARNING: Gas line hookup should be done by your
gas supplier or a qualified service person.
WARNING: Before you proceed, make sure your
gas supply is OFF.
The appliance and it's individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing of
gas supply piping system at test pressures in excess of 1/2 psi (3.5
kPa). Appliance must be isolated from gas supply piping system
by closing its individual manual shutoff valve during any pressure
testing of gas supply piping system at test pressures equal to or less
than 1/2 psi (3.5 kPa).
A manual shutoff valve has been included in the appliance's gas sup-
ply system. You may consider installing an extra gas shutoff valve
outside the appliance's enclosure (check with local codes) where
it can be accessed more conveniently with a key through a wall as
shown in Figure 14, page 13.
In conformance with local codes, route a 1/2" NPT gas line towards
appliance coming in from any of the 3 directions shown in Figure 15.
CAUTION: Do not kink flexible gas line.
Battery Cover
12 Volt Battery
Back of
Handset
Pull to Remove
Insulation Tab
126746-01D