3. Use the arrow keys or the top right jog wheel to scroll through the existing steps.
4. To create a new step after the last one, press [LOAD] and follow steps 5-10.
To insert a step before the current step, hold [SHIFT] while you press [LOAD] and follow steps 5-10.
To delete the current step, press [CLEAR]. Go to step 10
5. Press a page key, followed by a general purpose number key to select the cue you wish to attach to this
step. Example: Select cue 1/01.
6. Use the second softkey on the right hand side to toggle between the step options: WAIT, FOLLOW, GOTO,
LOOP, LAMP_ON, LAMP_RESET, LAMP_OFF and GO. Example: Select the WAIT option.
7. Depending on the step option you choose, you have to set different parameters. Example: 'WAIT' comes
the parameter wait time (WT).
8. Press the softkey next to the parameter value to adjust it. Example: Press {WT -> 0.0 S}.
Use the top right jog wheel to increment/decrement the value.
If you want to input a completely new value, hold [CLEAR] until the value reads 0.0. Use general purpose
number keys 1-10 to input a new value (use 10 to enter a 0). Example: 10 seconds.
9. Press [ENT] to confirm or [ESC] to leave the value unchanged.
10. Go to step 3 until you are done editing the list.
11. Press [STORE] to store the cue list to memory. Press any key to confirm the message that follows.
12. Press [ESC] to leave the cue list editor. Xciter will return to cue list selection where you can launch the cue
list.
Xciter user manual
Run mode features
107