Installation Diagram Of Indoor And Outdoor Units - Toshiba RAS-24SKP-ES2 Service Manual

Split wall type
Table of Contents

Advertisement

8-2. Installation Diagram of Indoor and Outdoor Units

5
TOSHIBA New IAQ filter
6
3
Batteries
TOSHIBA New IAQ filter
2
Wireless remote control
• Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (- ) positions.
8
4
Pan head
Remote control holder
wood screw
Vinyl tape
Apply after carrying
out a drainage test.
Before installing the wireless remote controller
– 32 –
Hook
1
Installation
plate
Shield pipe
Saddle
Extension
drain hose
(Not available,
provided by installer)
2 Wireless remote controller
FILE NO. SVM-10049
For the rear left and left piping
Wall
Insert the cushion between the
indoor unit and wall, and tilt the
indoor unit for better operation.
Do not allow the drain hose to get
slack.
Cut the piping
hole sloped
slightly.
Make sure to run the drain hose
sloped downward.
The auxiliary piping can be
connected to the left, rear left, rear
right, right, bottom right or bottom
left.
Right
Rear right
Rear
Bottom right
left
Bottom left
Insulate the refrigerant pipes
separately with insulation, not
together.
8 mm thick heat resisting
polyethylene foam
3 Batteries
Left