4-3. Indoor Unit (RAS-24SKHP-ES2)
No.
Parts name
1
Fan motor (for indoor)
2
Thermo sensor (TA-sensor)
3
Switching Transformer (T01)
4
Microcontroller
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01)
7
Diode (DB01)
8
Capacitor (C03)
9
Fuse (F01)
10
Varistor (R09, R10)
11
Resistor (R01)
12
Louver motor

4-4. Outdoor Unit (RAS-24S2AH-ES2)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
Solenoid coil
5
(for 4-way valve)
6
Thermo sensor
7
Magnetic contactor
8
Transformer
9
Microcontroller
10
Varistor (R73, R74)
11
Fuse (F01)
Type
MF-340-30-1RT
———
SWT-77
TMP87CM40ANG-6P68
———
LC*SS11V-R06270
D3SBA60
EKMH451VSN121MQ35S
BET6.3A
SR561K14DO
RF-5TK1R8
MP24Z3T
Type
Output (Rated) 2000W, 2poles, 1 phase, 220 − 240V, 50Hz
PA271X3CS-4MU2 Winding resistance (Ω)
(at 20°C)
Output (Rated) 42W, 4poles, 1 phase, 220 – 240V, 50Hz
FG-240-42A-1
Winding resistance (Ω)
(at 20°C)
DS451305NPQB AC 450V, 3.0µF
B32332I5606J063 AC 450V, 60µF
VHV (STF)
AC 220 ~ 240V
TE / TD
10kΩ at 25°C / 50kΩ at 25°C
A35P
220 ~ 240V, 50Hz
TT-05
220 ~ 240V
TMP47C840N
15G471K
470V
TSCR
T6.3A, 250V
– 11 –
FILE NO. SVM-10049
Specifications
DC 340V, 30W
10 kΩ at 25°C
DC 7V, 12V
10 kΩ at 25°C
27mH, 600mA
4 A, 600 V
120 µF, 450 V
6.3 A, 250 V
560 V
1.8Ω , 5W
Output (Rated) 2 W, 16 poles, 4 phase,
DC 12 V
Specifications
Red-Black
1.27
Red-Black
70.5
White-Black
2.10
White-Black
120.1