Indoor Unit - Toshiba RAS-24SKP-ES2 Service Manual

Split wall type
Table of Contents

Advertisement

8-4. Indoor Unit

8-4-1. Installation Place
• A place which provides enough spaces around the
indoor unit as shown in the diagram.
• A place where there are no obstacle near the air
inlet and outlet.
• A place which allows easy installation of the piping
to the outdoor unit.
• A place which allows the front panel to be opened.
• The indoor unit shall be installed so that the top of
the indoor unit is positioned at least 2m in height.
• Also, avoid putting anything on the top of the
indoor unit.
CAUTION
• Direct sunlight on the indoor unit wireless
receiver should be avoided.
• The microprocessor in the indoor unit should
not be too close to r-f sources.
(For details, see the owner's manual.)
<Remote control>
• Should be placed where there are no obstacles,
such as curtains, that may block the signal.
• Do not install the remote controller in a place
exposed to direct sunlight or close to a heating
source, such as a stove.
• Keep the remote controller at least 1 m away from
the nearest TV set or stereo equipment.
(This is necessary to prevent image disturbances or
noise interference.)
• The location of the remote controller should be
determined as shown below.
(Side view)
(Top view)
Reception
Remote
range
controller
Fig. 8-4-1
Indoor unit
Reception
range
Remote controller
8-4-2. Drilling a Hole and Mounting Instal-
lation Plate
<Drilling a hole>
When install the refrigerant pipes from the rear.
35
The center of the pipe hole is above
the arrow.
1. After determining the pipe hole position on the
installation plate (
mm) at a slight downward slant to the outdoor
side.
NOTE :
• When drilling into a wall that contains a metal lath,
wire lath or metal plate, be sure to use a pipe hole
brim ring sold separately.
<Mounting the installation plate>
170
To unit out line
240mm
85
Pipe hole
Hook
Indoor unit
– 36 –
FILE NO. SVM-10049
23mm
120
180
240
Pipe hole
dia.65mm
Fig. 8-4-2
ð
) drill the pipe hole (Ø65
Anchor bolt holes
Hook
To unit out line
240mm
To unit out line
35mm
To unit out line
120mm
240
180
35
120
23
0
Hook
Thread
Mounting
7
1
Screw
Weight
Fig. 8-4-3
170
132
23
Pipe hole (dia. 65mm)
Installation
plate

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-24sa-es2Ras-24s2ah-es2Ras-24skhp-es2