8-6-2. Test Operation

To switch the TEST RUN (COOL) mode, press RESET
button for 10 seconds (The beeper will make a short beep).
Hi P OWE R F ILT E R
RESET button
Fig. 8-6-3

8-6-3. Auto Restart Setting

This product is designed so that, after a power failure, it
can restart automatically in the same operating mode as
before the power failure.
Information
The product was shipped with Auto Restart
function in the OFF position.
Turn it ON as required.
<How to Set the Auto Restart>
1. Press and hold the RESET button on the indoor unit for 3
seconds to set the operation. (3 beep sound and
OPERATION lamp blink 5 time/sec for 5 seconds)
2. Press and hold the RESET button on the indoor unit for 3
seconds to cancel the operation. (3 beep sound but
OPERATION lamp does not blink)
• In case of ON timer or OFF timer are set, AUTO RESTART
OPERATION does not activate.
P AP
T IME R
OP E R AT ION
RESET
8-6-4. Remote Controller A or B Selection
Setting
When two indoor units are installed in the separated rooms, it
is not necessary to change the selector switches.
<Remote control A or B Selection>
When two indoor units are installed in the same room or
adjacent two rooms, if operating a unit, two units may receive
the remote control signal simultaneously and operate. In this
case, the operation can be preserved by setting either one
ndoor unit or remote control to B setting. (Both are set to A
i
setting in factory shipment.)
The remote control signal is not received when the settings of
indoor unit and remote control are different.
There is no relation between A setting/B setting and A room/B
room when connecting the piping and cables.
<Remote Control A-B Selection>
To separate using of remote control for each indoor unit in case
of 2 air conditioner are installed nearly.
the remote control signal simultaneously and operate. In this
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold CHK
pencil. "00" will be shown on the display.
4. Press
MODE during pushing CHK , "B" will show on the display
and"00" will disappear and the air conditioner will turn OFF. The
Remote Control B is memorized.
Note : 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A have not "A" display.
3. Detault setting of Remote Control from factory is A.
"B" Display
"00" Display
− 45 −
FILE NO. SVM-10049
button on the Remote Control by the tip of the
PRESET
FAN
ONE-TOUCH
MODE
COMFORT
QUIET
SELECT
SWING
FIX
Hi-POWER
ECO
CLR
TIMER
ON
OFF
SLEEP
SET
CHK
FILTER
CLOCK
Fig. 8-6-4